12.07.2015 Views

Altistart 22 - Schneider Electric

Altistart 22 - Schneider Electric

Altistart 22 - Schneider Electric

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WiringThe ATS<strong>22</strong>pppQ range (230-440 V) can be connected in the motor supply line or inside delta connection of the motor.The <strong>Altistart</strong> <strong>22</strong> in line connectionThe motor connection depends on the supply voltage. Two possibilities are shown below: star connection and delta connection.ATS<strong>22</strong>MotorStar connectionDelta connectionThe <strong>Altistart</strong> <strong>22</strong> connected inside delta connectionATS<strong>22</strong>NOTICERISK OF DAMAGE TO THE SOFT STARTER• Only the ATS<strong>22</strong>pppQ range can be installed inside delta connection.• Ensure connection exactly as shown on the example.• Line voltage should not exceed 440 V.• The parameter dLtA must be set to dLt.Failure to follow these instructions can result in equipment damage.Note: Phase sequence must be 1 - 2 - 3Motor30 BBV51330 08/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!