WiringThe ATS<strong>22</strong>pppQ range (230-440 V) can be connected in the motor supply line or inside delta connection of the motor.The <strong>Altistart</strong> <strong>22</strong> in line connectionThe motor connection depends on the supply voltage. Two possibilities are shown below: star connection and delta connection.ATS<strong>22</strong>MotorStar connectionDelta connectionThe <strong>Altistart</strong> <strong>22</strong> connected inside delta connectionATS<strong>22</strong>NOTICERISK OF DAMAGE TO THE SOFT STARTER• Only the ATS<strong>22</strong>pppQ range can be installed inside delta connection.• Ensure connection exactly as shown on the example.• Line voltage should not exceed 440 V.• The parameter dLtA must be set to dLt.Failure to follow these instructions can result in equipment damage.Note: Phase sequence must be 1 - 2 - 3Motor30 BBV51330 08/2012