Configuration menu (ConF)conFCode Name/Description R/W Adjustment range Factory settingConfiguration menuIcL M Soft starter rated current R According to the softstarter ratingdLtAMaximum rated continuous current of the soft starter (see pages 11 and on the Quickstart annex (S1A14738)).IcL value is on the soft starter nameplate (Soft starter FLA). Read only parameter between 17 A and 590 A.M Connection typeNOTICERISK OF DAMAGE TO THE SOFT STARTERR/W*• This parameter must be set in accordance with the wiring type, see page 30.• When dLtA is set to dLt:- Only the ATS<strong>22</strong>pppQ range can be installed inside delta connection.- Ensure connection exactly as shown page 30.- Line voltage should not exceed 440 V.Failure to follow these instructions can result in equipment damage.LInELInEdLtUlnInCodnLOCLOCLACoFFOnv Line: in line connectionv Inside delta connection of the motor.Parameters automatically set when dLtA = dLtParameter Set Descriptioncode valuebSt 0 Boost time, see page 53SSC oFF Start-stop control, see page 54SPCU 0 Start-stop profile control voltage, see page 54PHr 123 Phase sequence, see page 57EdC inactive End of deceleration, see page 52M Line voltageR/WQ range:200 to 440 VS6-S6U ranges:200 to 600 VQ range:400 VS6-S6U ranges:480 VSet to the nominal voltage of the mains.Note: Improper setting may cause unnecessary tripping, because Uln is the reference for over voltage and undervoltage protections.M Motor rated currentR/W*0.4 IcLup to IcL• Soft starter in line connection:In = rated current of the motor.• Soft starter inside delta connection:In = rated current of the motor / √3.M Setting lockR/WAccording to thesoft starter rating(pages 11 to <strong>22</strong>)nLOCUsed to enable or disable parameters modification on the displays.v not locked: all R/W parameters can be modified. Also accessible with key combinationv locked: all parameters are read only on local display or remote keypad display (the parameters can bestill modified by serial link and SoMove software).M Advanced modeAllows you to access to the Advanced level, see page 46 for detailed description.v off: Easy start up levelv on: Advanced levelNote: It also allows to display a longer trip history list:LAC set to oFF: Total number of trips dEFtand Trip history 1 dEF1, page 63.LAC set to On: Total number of trips dEFt and Trip history 1 dEF1 to Trip history 9 dEF9,page 63.R/WoFF*: Write only when the soft starter is stopped50 BBV51330 08/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!