Owner's Manual - Hearth & Home Technologies
Owner's Manual - Hearth & Home Technologies
Owner's Manual - Hearth & Home Technologies
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
J. Existing Masonry ChimneyType ACHIMNEY LINERTERMINATION CAP PART#923GKType BCHIMNEY LINER TERMINATIONCAP PART #923GK30 ft. (9 m) OF 3 in. (76 mm)FLEX LINER EXHAUSTSECTION3 IN. (76 MM) FLEX LINERTHIS SECTION OF THECHIMNEY MUST BE SEALEDCO-AXIAL TO CO-LINEARCONNECTOR PART#923GCLCO-AXIAL TO CO-LINEARCONNECTOR PART #923GCLPIPE LENGTH(OPTIONAL)PIPE LENGTH(OPTIONAL)THE CHIMNEY MUST BESEALED FROM THE 4 ft. (1 m)SECTION TO TERMINATIONUSING A SMOKE SHELF OR ADAMPER. THE SEAL SHOULDBE 6 in. (152 mm) BELOW THEEND OF THE 4 ft. (1 m) AIRINTAKE SECTION.SHOWING TWO 30 FT.(9 M) SECTIONS OFFLEX LINER4 ft. (1 m) OF 3 in. (76 mm)FLEX LINER“AIR INTAKE SECTION”Type C - Up & Out InstallationType D - <strong>Hearth</strong> MountTERMINATION CAPPART #SLK-991DACHIMNEY LINERTERMINATION CAPPART #923GKTOP ADAPTERFLASHING30 FT. (9 m) OF 3 IN. (76 mm)FLEX LINEREXHAUST SECTIONRETROCONNECTOR4 in. (102 mm)FLEX LINERTHIS SECTION OFTHE CHIMNEY MUSTBE SEALED90º ELBOWDIRECTVENT PIPEALCOVE CLEARANCE TOCOMBUSTIBLES MUST BEMAINTAINEDCHIMNEY MUST BE SEALEDFROM 4 FT. (1 m) SECTION TOTERMINATION USING A SMOKESHELF OR A DAMPER*.SEAL SHOULD BE 6 IN. (152 mm)BELOW END OF 4 FT. (1 m) AIRINTAKE SECTION.4 FT. (1 m) OF 3 IN. (76 mm)FLEX LINERAIR INTAKE SECTIONCO-AXIAL TO CO-LINEARCONNECTOR PART# 923GCLFigure 5.24*NOTE: In the Commonwealth of Massachusetts, the word damper shallbe replaced with the words flue restrictor.Heat & Glo • Paloma • 7031-220 Rev. S • 8/09 21