EXECUTIVE SUMMARY<br />

PRELIMINARY AUDIT REPORT<br />

IMPROVING COMBUSTION EFFICIENCY<br />

BURSHTYN POWER PLANT<br />

(Oct. 8 Thru Oct. 11, 1994)<br />

The preliminary audit activities consist of a reconnaissance visit made to the plant to meet<br />

with key plant personnel, to establish local contacts, to collect information regarding boilers,<br />

combustion process and controls, fuel management and general plant operations.<br />

The energy saving program consists of providing instrumentation equipment to improve<br />

combustion efficiency of the boilers, as a first step towards the life extension of the plant.<br />

The implementation of this program is in two phases. During the first phase in order to<br />

demonstrate the improvement of boiler's combustion efficiency, the instruments to be<br />

installed are listed under Low-Cost, No-Cost Short Term Recommendations and are related<br />

to one boiler except as noted. Based on operation results the program may be expanded to<br />

the balance of the boilers in the plant. Implementation of the second phase is addressed<br />

under the Medium to Long-Term Recommendations.<br />

Based on the preliminary survey of this plant the following are Low-Cost, No-Cost Short<br />

Term and Medium and Long Term recommendations:<br />

Low-Cost. No-Cost Short Term Recommendations<br />

1) One (1) Portable combustion analyzer (with spare cells) with probes<br />

2) One (1) Laptop computer with software<br />

3) One (1) Heat spy (portable infrared temperature monitor)<br />

4) One (1) Portable multimeter ac power analyzer<br />

5) One (1) On-line calorimeter for natural gas (Kcal/Nm 3 , Wobbe index)<br />

6) One (1) Mazut flowmeter for 159 mm diameter supply line<br />

7) One (1) Mazut flowmeter for 60 mm diameter return line<br />

8) Eight (8) Mazut tank ultrasonic level transmitters<br />

5906-02JPAR.5/<strong>12</strong>19194 1