EXECUTIVE SUMMARY<br />
PRELIMINARY AUDIT REPORT<br />
IMPROVING COMBUSTION EFFICIENCY<br />
BURSHTYN POWER PLANT<br />
(Oct. 8 Thru Oct. 11, 1994)<br />
The preliminary audit activities consist of a reconnaissance visit made to the plant to meet<br />
with key plant personnel, to establish local contacts, to collect information regarding boilers,<br />
combustion process and controls, fuel management and general plant operations.<br />
The energy saving program consists of providing instrumentation equipment to improve<br />
combustion efficiency of the boilers, as a first step towards the life extension of the plant.<br />
The implementation of this program is in two phases. During the first phase in order to<br />
demonstrate the improvement of boiler's combustion efficiency, the instruments to be<br />
installed are listed under Low-Cost, No-Cost Short Term Recommendations and are related<br />
to one boiler except as noted. Based on operation results the program may be expanded to<br />
the balance of the boilers in the plant. Implementation of the second phase is addressed<br />
under the Medium to Long-Term Recommendations.<br />
Based on the preliminary survey of this plant the following are Low-Cost, No-Cost Short<br />
Term and Medium and Long Term recommendations:<br />
Low-Cost. No-Cost Short Term Recommendations<br />
1) One (1) Portable combustion analyzer (with spare cells) with probes<br />
2) One (1) Laptop computer with software<br />
3) One (1) Heat spy (portable infrared temperature monitor)<br />
4) One (1) Portable multimeter ac power analyzer<br />
5) One (1) On-line calorimeter for natural gas (Kcal/Nm 3 , Wobbe index)<br />
6) One (1) Mazut flowmeter for 159 mm diameter supply line<br />
7) One (1) Mazut flowmeter for 60 mm diameter return line<br />
8) Eight (8) Mazut tank ultrasonic level transmitters<br />
5906-02JPAR.5/<strong>12</strong>19194 1