4"12-Z 1 - part - usaid
4"12-Z 1 - part - usaid
4"12-Z 1 - part - usaid
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Vladimir Pachura - SeniorMaster. Head of Automation De<strong>part</strong>ment<br />
AnatollJ Propopenko - Electrical Specialist<br />
Vaslly Bokly - Infrared Thermometer<br />
Andrey Kolobayev - Fluke power analyzer, Ultrasonic flow meter<br />
INSTRUMENTS SUPPLIED TO KRIVOI RaG TPP<br />
Zirtek oxygen analyzers, 4 probes for 2 bOIlers, 2-two channel analyzers<br />
Panametncs two channel ultraSOnic flow meter<br />
Instromet natural gas chromatograph, display Unit and accessones<br />
Oxygen cell and consumables for Enerac<br />
DISCUSSION<br />
Of all the personal contacts made In February, 1995, we met only one person, Peter<br />
Solovey - Chief of Maintenance De<strong>part</strong>ment The former Chief Engineer, Vladimir<br />
Luchnlkov was promoted two years ago to First Deputy MInister of Energy In Kiev The<br />
new Chief Engineer - Vladlmer Soroka was promoted from the BOiler De<strong>part</strong>ment He was<br />
very busy and did not seem to be familiar With the work we were dOing<br />
There IS a Canadian company at the plant working on "Group Project Implementation", a<br />
$260 million World Bank loan for rehabilitation of Units 6, 7 & 8 It was said that they are<br />
prepanng tenders ThiS firm has Installed a satellite system for telephone, fax and E-mail<br />
They find the Enerac combustion analyzer to be very good compared to other Instruments<br />
However, they do not see any advantages to use It effectively In thIS plant on the<br />
supercntlcal bOilers, as there are no appropnate measunng ports They claim that the<br />
Instrument IS expensive to maintain, requlnng calibration every three months, With a<br />
calibration gas kit which they do not have Also, the oxygen sensor must be replaced<br />
every year They recently received a new sensor, but haven't Installed It yet because they<br />
cannot calibrate It (supplemental calibration gas kits have been reordered for each plant)<br />
The Infrared thermometer IS used a lot In the Electncal De<strong>part</strong>ment for checking contacts<br />
Mechanical techniCians use It on generator and turbine where they cannot measure direct<br />
It IS used for routine maintenance measunng hot spots on bus connections, at dlstnbutlon<br />
substation, on motors, bearings, transformer bushings, Insulators, etc They now use the<br />
Infrared thermometer In place of manual hand test for rotor and stator "hot spots" They<br />
also use It on heat exchangers to find scale and sludge bUild-up In heat exchangers<br />
Sometimes the technical people Will not belIeve the Instruments, but Will trust their<br />
expenence or hand or senses An example IS for coal mill bearings where many have<br />
been destroyed. but the Infrared thermometer can find hot spots qUickly and save a lot of<br />
money It would be very useful for operations to have thiS Instrument. everybody who<br />
needs It, Instead of one man It would be best for each control room to have one<br />
Last Monday, 21 July. they started uSing the Panametncs ultraSOnic flow meter to measure<br />
2