1 PTVM-100, Station 2 - adjustment of the furnace mode, ecological, heat and<br />
technical adjustment with optimization of the exhausted harmful substances<br />
At the enterprises of Odessa Heat Supply Network'<br />
1 There were carned out ecological, heat and technical tests of the water heating<br />
bOIlers at the following bOiler houses<br />
Severnaya-1 <br />
Northern<br />
Yuzhnaya-1 <br />
Southern<br />
Chuboska -<br />
BOilers PTVM-50, No 1 and 2<br />
BOilers PTVM-1 00 I No 3 and 4<br />
Boilers PTVM-50, No 1,2,3 and 4<br />
BOIlers KBGM-50, No 3 and 5<br />
Besides on the steam boilers of Odessa Steam Power Plant they regularly carned out work<br />
aimed at correcting the mode gUidelines after a long term non-operation of the equipment,<br />
In case of operating the bOilers, on a combined fuel (gas + mazut), determination of the<br />
operation charactenstlcs of the bOilers on the ground of the results of the gas analySIS<br />
(leakages along the gas path of bOIler) There were also carned out express tests of the<br />
bOilers before their repair and after repairing to evaluate the fulfilled repair works<br />
CONCLUSIONS<br />
DUring the period of operation of the Instrument Enerac 2000, the speCialists from the<br />
group for adjustment of the heat and technical eqUipment of Enterprise Adjustment one<br />
can come to the following conclUSions<br />
Operation of the Instrument for determination and adjustment of the optimal<br />
combustion mode for a set load gives reduction of the working time by 50-60%<br />
The effiCiency of carrying out of adjustment and regulation (controlling) of the<br />
furnace process as the bOiler IS rising on account of reduction of the time for making<br />
samples, and It Increases the capacity of the bOiler by 0 8 - 1 2% due to the<br />
preCISion of the Instrument readings<br />
Work With the Instrument Enerac 2000 IS of large effect In the work of the operations<br />
people of the bOilers concerning corrections of the furnace mode when working In<br />
the non-stationary modes of the bOiler work, as well as It gives a large reduction of<br />
time when fulfilling the mode and adjustment and also ecological and heat and<br />
technical tests of a bOiler With the aim of making the mode gUidehnes as well as the<br />
ecological and heat and technical charactenstlcs of the bOiler<br />
Remarks (or comments) (concerning the organization and service maintenance)<br />
9