.- The <strong>12</strong>61<br />

Calorimeter<br />

Operates in a compact, self-contained<br />

jacket with a built-in oxygen filling<br />

system.<br />

EFFECTIVE THERMAL JACKETING<br />

Outstanding thermal Jacketing IS provided In the<br />

<strong>12</strong>61 Calorimeter by a circulating water system which<br />

maintainS a forced flow around the sides and bottom<br />

of the bucket chamber and through the cover as well.<br />

The water In this system IS recirculated continuously<br />

by a bUilt-in, high capacity pump. Since all tests are<br />

run by Isoperlbol methods, the Jacket temperature<br />

remaIns constant dUring a run and no water<br />

additions are needed. Also, no water additions or<br />

waiting period are required at the end of a run since<br />

the jacket does not have to be recycled back to a<br />

fixed starting temperature. Jacket heating IS provided<br />

by a sealed ImmerSion heater operated by the<br />

calorimeter controller In conjunction with a bUilt-in<br />

thermistor probe.<br />

MOLDED FIBERGLASS AND<br />

BRASS CONSTRUCTION<br />

To ensure minimal heat leak and long service life,<br />

both the outer case and the water jacket are made of<br />

a high strength, compression molded, fiberglass<br />

reinforced polyester resin. These <strong>part</strong>s are<br />

assembled Into a sturdy, light weight structure which<br />

can be used wIth aCidic water supplies or In a<br />

corrosive laboratory atmosphere without damage to<br />

the Instrument. The Inner bucket chamber IS made of<br />

nickel brass for good corrosion resistance and<br />

proven heat transfer characteristics.<br />

A RELIABLE OXYGEN BOMB<br />

Each <strong>12</strong>61 Calorimeter IS equipped wIth a Parr<br />

1108 Oxygen Bomb In which samples can be burned<br />

completely and safely with full recovery of all<br />

combustion products. The bomb IS held In an oval<br />

bucket, covered with two liters of water. An Impeller<br />

driven by a motor mounted Within the cover produces<br />

excellent Circulation around the bomb.<br />

A BUILT-IN OXYGEN FILLING SYSTEM<br />

To Increase the speed, reliability and safety of the<br />

bomb filling operation, the <strong>12</strong>61 CalOrimeter has a<br />

bUIlt-in automatic system for filling the bomb WIth<br />

oxygen to the desired operating pressure ThiS IS<br />

Installed Within the calOrimeter, leaving only a short<br />

filling hose extending from the Jacket To fill the bomb<br />

the operator SImply slips a connectIOn fitting onto the<br />

bomb Inlet valve and pushes a button to start the<br />

filling sequence Filling then proceeds automatIcally<br />

at a controlled rate to a pre-set pressure. He then lifts<br />

the connector from the bomb and proceeds WIth the<br />

test. If. for any reason, the bomb pressure did not<br />

reach the desired level, an error message Will<br />

indicate a low charge The filling rate IS regulated so<br />

that oxygen enters the bomb at a Uniform, controlled<br />

rate, avOiding any sudden blast that might blow a<br />

powdered sample out of the combustion cup. Safety<br />

provisions are Included to prevent an aCCidental<br />

overcharge to the full pressure of the oxygen supply<br />

tank.<br />

PREaSE ELECTRONIC THERMONIETRY<br />

Temperatures are measured with a high preCISion<br />

electrOniC thermometer bUilt Into the calOrimeter,<br />

uSing a speCially deSigned thermistor network to<br />

obtain excellent linearity and high resolution In<br />

differential temperature measurements. ThiS custom<br />

deSigned system WIth ItS associated software<br />

provides a umform scale over a Wide range of<br />

operating temperatures so that the energy eqUIvalent<br />

(EE value) for the calOrimeter remains remarkably<br />

constant as compared With less stable systems uSing<br />

diodes or other temperature sensors ThiS stability IS<br />

confmned by many users who report that they find It<br />

necessary to recheck the energy eqUivalent only<br />

once or twice monthly unless a major component of<br />

the system has been changed.<br />

The temperature sensor IS sealed In a 118" dla<br />

stainless steel probe held In a fixed mounting on the<br />

calOrimeter cover, where It IS raised and lowered With<br />

the cover Measurements over the 20 0 to 40 0 C<br />

workmg range can be obtained With 0.0001 0 C<br />

resolution The absolute accuracy IS less precise<br />

(+1-a 1 0 C) but thiS does not affect differential<br />

measurements. Tailored software converts all<br />

readings to CelSIUS values Instead of ambIguous<br />

resistance umts No mercurial thermometers are<br />

required.