Information system for the plant and would like to combine the data from all instruments<br />

into one program He has wntten a program In C-Ianguage for downloading data from the<br />

Panametrics He asked where IS the program from Panametncs for downloading data to<br />

a computer They use the flow meter every day for measunng hot water flow and mazut<br />

flow to bOilers<br />

They do not have a program diskette for the Enerac S N 11003252. They used to buy<br />

reference gases to calibrate Instruments In plant, but now calibrate the Enerac and use It<br />

to check other Instruments But they cannot use It to plot and analyze data on the pnnter<br />

as descnbed In the manual, and wonder If there IS special software to make it work We<br />

were given a document shOWing calculation of efficiency and energy savings of about<br />

$34,000 dunng 1995 using the Enerac We were also given a document from the Central<br />

Cnmean Regional De<strong>part</strong>ment of EnVironmental Protection regarding a dispute In<br />

companson of Inspector uSing coloremetnc burettes to test flu gas vs Enerac readings<br />

always being lower and a requirement to do parallel tests WIth the Donorgres Laboratory<br />

"TESTO-33" Instrument<br />

The Electrrcal De<strong>part</strong>ment has been uSing the Fluke power analyzer extensively to<br />

measure current, voltage and phase angles With very good results They measure voltage<br />

on busses, current on current transformers<br />

The accuracy of the Fluke IS higher than measurrng equipment In the plant for measunng<br />

voltage and current They trust the Instrument very much and use It to check other<br />

measunng Instruments When testing phases on a group of transformers at the gas<br />

turbines, they found an unbalance They could perform maintenance on the scheme, but<br />

the cost would be higher than the energy losses<br />

They used the Fluke to try to find the weak POints In bOiler feedwater pump motors and<br />

Identified that stator Winding need to be replaced They also discovered that copper rotor<br />

bars end connecttons were weakenrng, resulting in losses The problem IS that these are<br />

old 3 KV motors no longer made, as 6 KV IS standard<br />

They also found a small 200W unbalance of about 20% at admlnrstratlon bUilding where<br />

one phase was overloaded and they corrected It The Important lesson IS that the Fluke<br />

IS useful for Identifying energy losses<br />

The Infrared thermometer Mlnolta Cyclops IS used to check for heat losses from bOilers,<br />

drum insulation, steam lines, etc They found bad insulation on a stream drum and<br />

replaced It They tned to check the accuracy of Instrument against a thermocouple and<br />

found 40°C dIfference They do not trust the accuracy, but saId they do not have a manual<br />

in RUSSian or table of emissivitles We mentioned that the Mlkrom manual was translated<br />

and should be Similar<br />

They used the Instrument to find a steam leak under Insulation In the main bUIlding They<br />

5