were starting a bOiler, 370°C, 40 kg/cm 2 and saw there was a problem, valve was<br />

steaming, not normal They measured insulation temperature difference near the valve<br />

and found a 10 cm crack on weld of 325 x 24 mm pipe<br />

We went to the power plant control room to look at the Instromet Encal gas chromatograph<br />

(GC) display mounted In the main panel Above It IS mounted a data logger which can<br />

Input real time heat content from the GC to record total from metered gas flow At present,<br />

they Input a fixed value of KCal/cu m.<br />

We then went to the gas metering substation to see the GC installation They ran new<br />

shielded cable about 3000 ft from GC to control room display control Unit They took a<br />

sample line from downstream of Orifice meter run to control house where GC IS mounted<br />

on the wall They added a filter In the sample line with SIlica gel dlsslcant for removing<br />

mOisture and crude from gas sample All tubing and wIring IS Installed, waiting for<br />

calibration gases to clear customs In Kiev, so the startup engineer can travel to<br />

commiSSion the GC. Their biggest concern IS the need for a spare electrOniCs display<br />

board Attached IS a diagram of the system<br />

We went to look at the installation of oxygen analyzers on one of the two large hot water<br />

heating bOilers The electroniC two-channel analyzer display Unit was mounted In the bOIler<br />

control panel They mounted the probes below the observation ports on backpass of the<br />

boilers They made up an extra pair of flange-nozzles and Installed them In the second<br />

bOiler so the probes could be SWitched to that bOIler when operating.<br />

They mounted the reference air control panel between the two boilers with cable and<br />

copper air tubing run to both They found a very small air blower-compressor salvaged<br />

from an old hydrogen analyzer, which they mounted inside the cabinet<br />

We were prOVided with a table of consumption, heating values and prices for natural gas<br />

and mazut for 1996-1997, attached In-plant cost to produce electriCity IS 5 3 Kp/KWh<br />

(2 91 ¢/KWh), and Kremenergo sells at 711 Kp/KWh (3 91¢/KWh)<br />

Wed, July 30. 1997 - Travel to Odessa<br />

Thr & FrI, July 31-Aug 1,1997 -In Odessa CHP Plant<br />

PERSONS MET DURING MEETINGS<br />

George Vukovlch- Director<br />

• Oleg Yarotskl - Chief Engineer - Power Plant<br />

Sergey Donchenko - Chief of Instrumentation<br />

Valerie Gurburov - EqUipment Engineer<br />

Antonlna Ogorodnlkova - Chief Chemist<br />

INSTRUMENTS SUPPLIED TO ODESSA CHP PLANT<br />

Zirtek oxygen analyzers, 2 probes for one boiler, 1 two-channel analyzer<br />

6