paid December salary<br />
It IS difficult for employees to be motivated when last week they received only 20% of their<br />
February salary The power that the plant generates for domestic and export consumption<br />
IS paid for In bartered goods, not cash<br />
About the Enerac combustion analyzer, they asked why the manual has detailed<br />
Instructions for plotting and emiSSions analySIS, but the Instrument says "no function" The<br />
bUilt-in pnnter IS supposed to pnnt curves, but It does not work They can only get plots<br />
on computer screen by uSing Enercomp for Windows They had diSCUSSions With<br />
Uglegorsk power plant about the Enerac Also, the refresh diskette IS a 525 In floppy,<br />
whereas the Tllaptop has a 3 5 In drive Enerac S N 11003249 They used It for a while<br />
to measure CO2and NOx In flue gas<br />
They also have a German IMR combustion analyzer (1994) Similar to Enerac, which also<br />
needs an oxygen sensor, calibration gases and service, but no money to purchase<br />
They report that the Zeigler UNICON CEM system Installed on stack No 3 several years<br />
ago IS stili non-functional because they need calibration gases The probe In stack IS<br />
damaged because of lack of use and no maintenance They said $455,000 was wasted<br />
They said the amount of fines for emiSSions has decreased because the number of Units<br />
operating has decreased Fees (fines?) paid for emiSSions In 1996<br />
EmisSions<br />
Soot<br />
Sulfur Anhydride<br />
NOx<br />
CO<br />
V 20 S<br />
Hrvlna<br />
2<strong>12</strong>,588<br />
459,107<br />
76,352<br />
4,538<br />
404<br />
752,989 $413,732<br />
They also have a flue gas analyzer ANALIT-PRlBOR which was manufactured In Kiev It<br />
IS reported to be a microprocessor type photo sensitive spectrum analyzer measuring CO 2 ,<br />
CO, S02, NOx, NO, N0 2 , and haVing a long life The Instrument IS not portable, but<br />
compact In size and easily moved It was Installed on Unit 9 for awhile near I D fan, but<br />
removed because It was getting damaged In the dirty atmosphere<br />
The Infrared thermometer was used up until SIX months ago to find problems, but battenes<br />
died and they cannot find 2 Hrvlna ($1 10) to buy four new ones The electriCian used It<br />
to check a large "fuse" on a transmission tower which was overheating from a short CirCUit<br />
and could have been a serious safety Incident They used It to check Insulation and covers<br />
on bOiler burners They also used It to find and repair insulation on steam lines from<br />
bOilers They did not seem to be aware of other uses for checking temperatures of motors,<br />
bearings, contacts, etc The electnclans apparently refused to use It<br />
<strong>12</strong>