12.07.2015 Views

coulomb excitation data analysis codes; gosia 2007 - Physics and ...

coulomb excitation data analysis codes; gosia 2007 - Physics and ...

coulomb excitation data analysis codes; gosia 2007 - Physics and ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

......................................................................................................END, M<strong>and</strong>atory CONT flag marking the end of CONT input. Must be followd by a blank line.......................................................................................................FIX, This switch provides the easiest way to override the matrix elements setup specified by the MEinput. When FIX, is encountered all matrix elements are fixed <strong>and</strong> only those specified by subsequentinput are released for minimization or error estimation. Further input required:IMI(1),I(2)··I(IM)Thenumberofmatrixelementstobereleased.Indices of the matrix elements to be released (defined by the sequenceof the ME input).Using FIX, it is easy to reduce the number of free matrix elements without modifying the ME input........................................................................................................FMI, Fast minimization switch. Causes the code to terminate the job immediately after the OP,MINIstep was completed, without compiling the final output. FMI, provides substantial time saving when thefinal output is not needed since the compilation of the final OP,MINI output involves a full Coulomb<strong>excitation</strong> calculation. The remainder of the input, including the repeated OP,MINI comm<strong>and</strong>s isignored if the FMI, switch has been selected. FMI, cannot be used when the SEL, switch is set........................................................................................................INR, Independent normalization switch. Overrides the relative normalization of γ detectors <strong>and</strong> differentexperiments as specified in OP,YIEL input. With the INR, switch set, the code will calculate thebest normalization factors (i.e. the ones providing the minimum value of χ 2 for a given set of elements)for each single γ detector independently........................................................................................................INT,X.IE 1 ,IS, Overrides the default accuracy check parameter, IS, of the Adams-Moulton integration· routine for specified experiments. The accuracy check is made every IS steps,· with a resultant possible change in integration stepsize. The default value is IS =1,· thus the stepsize may be adjusted after each complete integration step. Setting· IS =1000effectively switches off thestepsizecontrolsince1000 steps exceeds theIE X ,IS X range of integration (according to 4.1), forcing the code to retain maximum accuracy.X has the meaning of the number of experiments for which the default is to be altered. Additionalinput consists of X records, IE n being the experiment number <strong>and</strong> IS n the accuracy control parameterfor this experiment. The experiments are numbered according to the sequence of the EXPT input,thus this control switch only can be used after the suboption EXPT definition........................................................................................................LCK, This switch allows fixing a series of matrix elements without modifying the initial setup, e.g. itcan be used to keep the matrix elements belonging to a given multipolarity fixed during minimization.It requires further input as follows:64

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!