12.07.2015 Views

Untitled

Untitled

Untitled

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DIJAGNOSTI»KI PREGLEDRASPADA ELEKTROENERGETSKOGSUSTAVA NA OTOKU RODOSUDIAGNOSTIC REVIEW OF ABLACKOUT IN RHODESProf Papazoglou, Th. M., PhD, Prof Papazoglou, M. T., PhD,The Technological Education Institute of Crete,P.P. Box 1939, Iraklio, Crete, GreeceProf Thalassinakis, E. J., PhD, Prof Tsichlakis, Ch., PhD, ProfHatziargyriou, N. D., PhD, The Greek Power Public Corporation,The testing Research and Standard Center ∑ DEH S.A.,32 Halkokondili Street, 10432 Athens, GreceU radu se daje tehniËka analiza jednog incidenta koji se dogodio 21. oæujka 2007. godine u00:50 sati u noÊi i doveo do dvosatnog potpunog raspada elektroenergetskog sustava na otokuRodosu. Analiza dogaappleanja temelji se na registriranim operativnim podacima kao i nalazima naterenu. Izvrπena je tehniËka analiza smetnji kako bi se utvrdili vjerojatni uzroci i Ëimbenici kojisu pridonijeli pojavi smetnji. S obzirom da se radi o izoliranom sustavu koji je osobito je osjetljivna poremeÊaje, ispitane su uloge zaπtite sustava kao i kolebanja proizvodnje vjetroelektranatijekom incidenta. IzvuËeni su zakljuËci od praktiËnog znaËenja i dane su preporuke korektivnihmjera koje valja provesti kako bi se u buduÊnosti sprijeËile takve smetnje.A technical review of an incident on March 21, 2007 that began at 00:50 a.m. and led to atwo-hour blackout of the island of Rhodes electric power system is presented with the completesequence, including all the relevant registered operational data as well as the on-site field findings.A technical analysis of the disturbance was performed to determine the probable causesand factors that contributed to the duration of the disturbance. Since the system is an isolatedone, it is particularly vulnerable to perturbations. The roles of system protection and wind powergeneration during the incident are examined. Conclusions of practical importance are drawn,including recommendations for corrective measures to be implemented for preventing disturbancesof this kind from reoccurring in the future.KljuËne rijeËi: izolirani elektroenergetski sustav, nestanak strujeKey words: blackout, isolated electric power systemPapazoglou, Th. M., Papazoglou, M. T., Thalassinakis, E. J., Tsichlakis, Ch., Hatziargyriou, N. D., DijagnostiËki..., Energija, god. 56(2007), br. 5., str. 608-617Papazoglou, Th. M., Papazoglou, M. T., Thalassinakis, E. J., Tsichlakis, Ch., Hatziargyriou, N. D., Diagnostic..., Energija, vol. 56(2007), No. 5, pp. 608-617608

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!