Aija Mālniece, Alberts Auzāns, Kristīne DrevinskaAORTIC LUMEN DIAMETER AND BLOODPRESSURE CHANGES DYNAMICS AFTERREPLACING AORTA ABDOMINALIS WITH PROSTHESISAortic diameter dynamics cranial from prosthesisTable 4AnimalnameAorticdiameterprioroperation/cmAorticdiameter 2weeks afteroperation/cmAorticdiameter 1month afteroperation/cmAorticdiameter 2month afteroperation/cmAorticdiameter 3month afteroperation/cmAorticdiameter 4month afteroperation/cmAorticdiameter 5month afteroperation/cmFiksā 0.780 - 0.790 0.795 0.788 0.760 0.775Poga 0.688 - 0.720 0.740 0.763 0.784 0.776Melnīte 0.811 - 0.837 0.833 0.849 0.833 0.892Brille 0.826 0.769 0.760 0.812 0.820 0.785 -Pienene 0.882 0.859 0.920 0.872 0.855 0.971 -Minne 0.753 0.786 0.827 0.812 0.780 - -Knīpa 0.758 0.793 0.753 0.726 - - -Smukā 0.721 0.701 0.731 0.731 - - -Bumbulīte 0.727 0.714 0.784 0.784 - - -Aortic diameter dynamics caudal from prosthesisTable 5AnimalnameAorticdiameterprioroperation/cmAorticdiameter 2weeks afteroperation/cmAorticdiameter 1month afteroperation/cmAorticdiameter 2month afteroperation/cmAorticdiameter 3month afteroperation/cmAorticdiameter 4month afteroperation/cmAorticdiameter 5month afteroperation/cmFiksā 0.780 - 0.760 0.769 0.760 0.744 0.780Poga 0.688 - 0.747 0.726 0.707 0.776 0.773Melnīte 0.811 - 0.846 0.826 0.826 0.830 0.820Brille 0.826 0.841 0.815 0.794 0.776 0.802 -Pienene 0.882 0.811 0.763 0.828 0.795 0.846 -Minne 0.753 0.820 0.814 0.814 0.859 - -Knīpa 0.758 0.694 0.688 0.678 - - -Smukā 0.721 0.811 0.727 0.727 - - -Bumbulīte 0.727 0.838 0.819 0.819 - - -from prostheses one and two months after theoperation at α = 0.05. Mentioned aortic diameterchanges are shown in Tables 4. and 5.Conclusions1. The study shows that the innovative aorticprostheses do not change in diameter after twomonth from the surgery.2. Surgery like abdominal aorta transplantation doesnot cause significant variations in blood pressureduring post operative period.3. To find out later reactions to synthetic vasculargraft, further observations are recommended.References1. Alcantara E.M., Marshall L.M., Rodriguez V.V., Rosado C.F. (2005) Mechanics of biomaterials: vasculargraft prostheses. Article for the course on Mechanics of Materials, University of Puerto Rico, Mayaguez,Porte Rico, pp. 1–25.2. Ao P.J., Hawthorne W.J., Visaretti M., Fletcher J.P. (2000) Development of intimal hyperplasia in sixdifferent vascular prostehses. European Journal of Vascular and Endivascular Surgery, 20, pp. 241–249.3. Egner B., Carr A., Brown S. (2007) Essential facts of blood pressure in dogs and cats. VBS VetVerlag,Babenhausen, Germany 227 p.4. Formichi M.J., Guidoin R.G., Jausseran J.M., Awad J.A., Johnston K.W., King M.W., Courbier R., MaroisM., Rouleau C., Batt M., Girard J.F., Gosselin C. (1988) Expanded PTFE prostheses as arterial substitutein humans: late pathological findings in 73 excised grafts. Annals of Vascular Surgery, 2, pp. 14–27.Research for Rural Development 2012215

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!