9 Safety Discharge Valve <strong>and</strong> Condensate Connections9.1 Safety Discharge ValveTake the safety discharge pipe, supplied in the pipe pack <strong>and</strong>the union nut <strong>and</strong> seal, supplied in the loose items pack <strong>and</strong>fit as shown in diagram 9.1.This must be extended, using not less than 15mm o.d. pipe,to discharge, in a visible position, outside the building, facingdownwards, preferably over a drain.To ease future servicing it is advisable to use a compressiontype fitting to extend the safety discharge valve tube.The pipe must have a continuous fall <strong>and</strong> be routed to aposition so that any discharge of water, possibly boiling,or steam cannot create any danger to persons, damage toproperty or external electrical components <strong>and</strong> wiring.126679.2 Condensate Trap <strong>and</strong> Siphonic DrainConnectionA flexible condensate outlet pipe is fitted <strong>and</strong> should be usedto couple the condensate trap <strong>and</strong> siphonic drain to a 22mmto 25mm O.D. non corrosive plastic pipe (overflow pipe), seediagram 8.2.IMPORTANT: Please remove the bung from the flexible pipebefore fitting to a drain outlet pipe.NOTE: the pipe should have a fall of a least 2.5 o 44mm/metreaway from the <strong>boiler</strong>.Condensate should, if possible be discharged into thehousehold internal drainage system. If this is not practicable,discharge can be allowed into the external household drainsor a purpose designed soak away, refer to diagram 9.2.It is recommended that any external condensate drain pipe isprotected <strong>and</strong> also preferably of 32mm diameter, to preventfreezing in adverse weather conditions.The condensate is discharged periodically in ‘slugs’ bysiphonic action.It is not necessary to provide air breaks or extra traps in thedischarge pipe as there is already a 75mm high trap insidethe <strong>boiler</strong>. Fitting an extra trap may cause the <strong>boiler</strong> siphon towork incorrectly.Refer to BS5546 or BS6798 for advice on disposal of <strong>boiler</strong>condensate.Diagram 9.119

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!