14 Fault FindingState list - To access the state lists the ‘-’ button must be pressed for longer than 5 seconds until it begins to flash ‘S’ <strong>and</strong>then a number to indicate the state. The state numbers are given below.STATE LISTSCentral heating modeS.00 no heating requiredS.01 fan pre-runS.02 pump pre-runS.03 ignitionS.04 burner onS.05 pump / fan overrunS.06 fan overrunS.07 pump overrunS.08 Anti cycling periodDomestic hot water modeS.10 domestic hot water dem<strong>and</strong>S.11 fan pre-runS.13 ignitionS.14 burner onS.15 pump / fan overrunS.16 fan overrunS.17 pump overrunDescriptionNORMAL OPERATINGSTATE FOR CH MODENORMAL OPERATINGSTATE FOR DHW MODE13011Preheat modeS.20 domestic hot water cycling mode activeS.21 fan pre-runS.22 Pump pre runS.23 ignitionS.24 burner onS.25 pump / fan overrunS.26 fan overrunS.27 pump overrunS.28 Anticycling periodNORMAL OPERATINGSTATE FOR PRE-HEAT MODESpecial cases of status messagesS.30 No Heating dem<strong>and</strong> from external controls 230V Check wiring in external controller.Check wiring at Installer Interface.S.31 summer mode Check CH setpoint / Check external controlsS.32 Antifreeze active – fan speed variation too high Check fan connection.– waiting during blocking functionS.34 frost protection active (Priority 4) Temperature below 8 O C - check thermistorconnection if this is not true.S.36 No Heating dem<strong>and</strong> from external controls 24V Check wiring in external controller.Check wiring at Installer Interface.S.42 Accesory Module is blocking burner operation Check accessory module.S.53 waiting time: temperature difference flow- return sensor too high (Check thermistor fit)S.54 waiting time: no water in system, temperature(gradient error) rise flow / return sensor too highCheck flow & return thermistor connections to pipes.Check harness connection to thermistor.Check harness wires are not trapped between anyinternal components.Check flow & return thermistor connections to pipes.Check harness connection to thermistor.Check harness wires are not trapped between anyinternal components.S.76 Waiting period – pressure sensor Check system pressure - default display.S.96 Return-Sensor check is running, dem<strong>and</strong> Check return thermistor connection to pipe.(DHW or heating) is blockedCheck harness connection to thermistor.S.97 Water pressure sensor check is running, Check connection to pressure sensor.dem<strong>and</strong> (DHW or heating) is blockedCheck pump has not seized.S.98 Flow / Return - sensor check is running, dem<strong>and</strong>(DHW or heating) is blocked.Check flow & return thermistor connections to pipes.Check harness connection to thermistor.Check harness wires are not trapped between anyinternal components.Diagram 14.751

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!