13 Servicing13.5 Condense Trap <strong>and</strong> Siphonic DrainThe condense trap <strong>and</strong> siphonic drain does not normally needservicing unless material deposits exceed beyond the <strong>service</strong>fill level, see diagram 13.13.To clean the condense trap remove the sump <strong>and</strong> rinse withwater.13.6 Casing panel seal checkNOTE: If the functional checks did not indicate poorcombustion then it is not necessary to <strong>service</strong> thiscomponent.Check the condition of the seal <strong>and</strong> replace if worn ordamaged.To replace remove the old seal <strong>and</strong> thoroughly clean thecasing surfaces. Fit the new seals, these are supplied to thecorrect lengths <strong>and</strong> are in four pieces, for use on the sides,top <strong>and</strong> bottom.13.7 Service CompletionRe-check the combustion as described at the beginning ofthis section.On completion of the <strong>service</strong> the “Benchmark” Service Recordshould be completed.SECURINGNUTS (6)FAN CLAMPINGBRACKETBURNER14410 14397Diagram 13.1213929SUMPSECURINGSCREWCONDENSE TRAPAND SIPHONIC DRAINSERVICEFILL LEVELDiagram 13.1346