13.07.2015 Views

10 CFR 50.71(e) - Maritime Administration - U.S. Department of ...

10 CFR 50.71(e) - Maritime Administration - U.S. Department of ...

10 CFR 50.71(e) - Maritime Administration - U.S. Department of ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Updated Final Safety Analysis Report - (STS-004-002)Table 13-1 Non-Radiological Area SummaryDeck/compartmentsNo. <strong>of</strong> areasevaluatedDose rate foundContamination foundNavigation Bridge Deck 8 Background All < backgroundBoat Deck <strong>10</strong> Background All < backgroundPromenade Deck 2 Background All < background“A” Deck 20 Background All < background“B” Deck 44 Background All < background“C” Deck 31 Background All < background“D” Deck 11 Background All < backgroundWeather Deck (“A” Deck) fwdand aft15 Background All < background14’ Flat Deck 5 Background All < backgroundHold Deck 6 38 μR/hour* All < backgroundCargo Hold Number 4 (aft) 5 250 μR/hour** All < backgroundMachinery Casing, boat to “C”Deck4 Background All < backgroundEngine and Control Rooms 8 Background All < backgroundHold Number 5, engineering space 2 Background All < background* Hold Deck had a pipe running under the deck plate in the passageway that read 38 μR/hour oncontact. This pipe ran through a portion <strong>of</strong> the crossover area also. The pipe is for theequipment drain and waste collection (PD) system. Lower dose rates were recorded at variousareas <strong>of</strong> the passageway above the deck plates.** Hold Number 4, “D” Deck Starboard, had readings on the aft bulkhead up to 250 μR/hour. Thisappears to be shine from the Cold Water Chemistry Lab, upper level [originally the RadiationMonitoring Room (C-deck level, forward <strong>of</strong> the reactor compartment Frames 99- <strong>10</strong>2)].13.1.4 Radiological AreasTable 13-2 provides a summary <strong>of</strong> radiological condition found during the evaluation <strong>of</strong> radiologicalareas excluding the containment vessel and the reactor compartment. The values listed aremaximums.Table 13-2 Radiological Area SummaryDeck/compartmentsDose ratefoundHot Chemistry Lab, “D” deck <strong>of</strong>f <strong>of</strong> the control room Background < <strong>10</strong>00Contaminationfound(dpm/<strong>10</strong>0cm 2 )Rev. VI 136

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!