Updated Final Safety Analysis Report - (STS-004-002)Existing 120 VAC sections <strong>of</strong> the Main Switchboard No. 2, and the EmergencySwitchboard are fed via new molded case circuit breakers.A simplified one line diagram <strong>of</strong> the original distribution system is shown in Figure 8-1. Thecurrent system is shown in Figure 8-2.8.5.2.2. Main Switchboard Description (Original)Supply breakers to deactivated, disabled and/or inactive equipment have been verified open.The main switchboard for the control <strong>of</strong> all normal power sources was located in the maincontrol room. This switchboard was divided into two 450-volt sections; each section was fed byone 1500 kW SSTG and one 750 kW ADG. The two 450-volt sections were permanentlydeenergized by installation <strong>of</strong> a shore power switchboard in 20<strong>10</strong>.Additionally, the main switchboard lineup included a 120-volt, three-phase, a-c bus; a 125-volt,d-c bus; and a 120-volt, a-c bus. All normal power requirements were served by these busesthrough group-control centers and power panels located throughout the ship.Main switchboard bus section 1 was fed by SSTG 1 or ADG 1. Bus section 2 was fed by SSTG2 or ADG 2.Main switchboard bus section 1 was fed by the shore connection, and, by way <strong>of</strong> a circuitbreaker, bus section 2 can be fed by the shore connection. Bus sections 1 and 2 were connectedtogether through a normally closed bus tie circuit breaker located in section 2.Bus section 1 includes a 125-volt, d-c bus which could have been fed from the followingsources that are deactivated, disabled and perform no active function:1. Bus section 1 by a 40 kW motor generator 1.2. Bus section 2 by a 40 kW motor generator 2.3. The 125-volt, d-c vital instrument bus floating battery.A 120-volt, single-phase, 60-cycle, a-c vital bus is also included in the bus section 1 lineup.The 120-volt, a-c final bus was fed by the two 25 kW motor generators which were connectedto the 125-volt, d-c bus. These motor generators are deactivated, disabled and perform noactive function.Bus section 2 includes a 120-volt, three-phase, 60-cycle bus fed from the Shore PowerSwitchboard after modifications in 20<strong>10</strong>. Originally, bus section 2 was fed from bus section 1or 2 by way <strong>of</strong> an automatic transfer switch and a bank <strong>of</strong> three 50 kVA transformers. Bussections 1 and 2 are also connected to the emergency switchboard byway <strong>of</strong> an automatictransfer system located on the emergency switchboard.All outgoing feeders from the 450-volt buses <strong>of</strong> the main switchboard were protected byWestinghouse Tri-Pac, molded-case circuit breakers with the exception <strong>of</strong> the drawout aircircuit breakers for the auxiliary propulsion motor. All outgoing feeders from the buses for125-volt dc, 120-volt, single-phase ac, and 120-volt, three-phase a-c are protected by moldedcasecircuit breakers.Rev. VI 79

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!