8.0 HART SMART CommunicationsThe MSM400 is compatible with the HART digital signalling system, either as well as the 4-20 mA output , or on aBus system. MSM400 supports Version 5.x of the HART protocol, and is fully supported by the MOBREY CK-1 HHC(Hand Held Communicator) and by the UNIVERSAL 275 HHC. It is normally necessary to load the Universal HHCwith the transmitters Device Description to access anything more than the basic transmitter information-contact<strong>Mobrey</strong> Measurement for details. The MSM400 can also communicate with the MOBREY H-View PC based system.Normal requirements of the loop impedance apply to allow the HHC to communicate properly. The MSM400 has abuilt in 270 ohm load, which can be selected if required-see section 4.6. This section also shows the specialterminals in the MSM400 terminal compartment available for connection of a HHC across the current output. TheMSM400 Cn number in relation to HART circuits is 1.Please consult the HHC manual to see how to interrogate the Universal and Transmitter specific parameters.The HART messages and Transmitter/Sensor ID Numbers are accessed and set up (where allowed) by the operator onthe INFORMATION Structure, APPLICATION+CONTROL UNIT+SENSOR screens. Some of this data is factory preset,and is not alterable, to make the MSM400 identifiable to Universal communicators. But the main Description, TagNumber and Message should be used to identify the equipment and the actual site application for site operator use.The Normal Universal Commands are always available over the HART interface---PV-Process Value% of current output (% of FSD)Actual mA current output being transmittedAlarms activeTemperature (inside the electronics housing)PV for 0 or 4 mA output as programmedPV for 20 mA output as programmedPV units of measurementTime Damping used on the measurementDescription (Customer supplied)Message (Customer supplied)Tag Number (Customer supplied)9. MAINTENANCE / INSPECTION9.1 SparesThe MSM400 is a factory built in instrument and apart from the mains fuse there are no spare parts that can befitted in the field. Should the MSM400 require any repair or replacement parts, it must be returned to <strong>Mobrey</strong>Measurement for action.CONTROL UNITNo maintenance is required beyond occasional cleaning of the enclosure with a damp cloth. Solvents or bleachesshould not be used. The fuse may only be replaced with the same type and rating. Do not modify or attempt torepair the unit.SENSORSNo maintenance is required beyond occasional cleaning. The frequency of cleaning will be determined byexperience. A message warning that cleaning is required may be generated when performing routine zerocalibrations. Refer to Section 6.130IP258

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!