<strong>HSD</strong><br />
9.11 ELECTRICAL CONNECTORS<br />
See the figures in chapter § 8 for the location of connections.<br />
D<br />
C<br />
E<br />
F<br />
A<br />
B<br />
Power connector<br />
(optional)<br />
A Motor phase “U”<br />
B Motor phase “V”<br />
C Motor phase “W”<br />
D Ground PE<br />
E Thermal switch for motor protection (*)<br />
F Thermal switch for motor protection (*)<br />
(*) E and F are the two terminals of a normally<br />
closed (ON) switch, which opens when the motor<br />
reaches a dangerous temperature.<br />
Sensor wiring<br />
1<br />
4 1 +Vcc<br />
3 3 0 V<br />
4 Output<br />
100<br />
5801H0066 en Rev.01 26/48<br />
G<br />
H A<br />
F<br />
K J<br />
E<br />
B<br />
D<br />
C<br />
Encoder connector<br />
(optional)<br />
A A +<br />
B A –<br />
C B –<br />
D GND<br />
E Z +<br />
F +Vcc 12 V DC ÷ 24 V DC �10%<br />
G Not used<br />
H Not used<br />
J B +<br />
K Z –<br />
Cable length : 1m<br />
Proximity sensor assembly<br />
PNP N.O.<br />
with M8 three-pin plug<br />
for sensor: S2, S3 (optional),<br />
S5<br />
Proximity sensor assembly<br />
PNP N.C.<br />
with M8 three-pin plug<br />
for sensor: S1