<strong>HSD</strong><br />

§ 15 TROUBLESHOOTING<br />

PROBLEMS CAUSES REMEDIES<br />

The electrospindle does<br />

not turn:<br />

There is no power<br />

No tool holder is fitted Fit a tool holder.<br />

The tool holder not correctly<br />

seated<br />

The thermal switch has tripped<br />

The inverter switch has tripped<br />

Sensor S1 or sensor S5 are<br />

disconnected or faulty<br />

� Check the mains power<br />

supply.<br />

� Check all power terminals.<br />

� Check all electrical cables and<br />

connections for breaks.<br />

See “The tool holder is not<br />

locked” below.<br />

Wait for the electrospindle to cool<br />

down and the thermal switch will<br />

automatically reset.<br />

If the thermal switch trips<br />

frequently, see “The<br />

electrospindle overheats” below.<br />

Consult the inverter's own manual<br />

or contact the inverter<br />

manufacturer.<br />

� Check the sensor connectors.<br />

� Check the sensor cables for<br />

breaks.<br />

� Contact the <strong>HSD</strong> technical<br />

assistance service.<br />

5801H0066 en Rev.01 44/48