<strong>UR51</strong> <strong>User</strong> <strong>Guide</strong><br />
within the serial frame interval.<br />
Table 4-4-1-2 DTU Parameters<br />
Item Description Default<br />
Transparent<br />
Protocol Select "TCP" or "UDP" protocol. TCP<br />
Keepalive<br />
Interval (s)<br />
Keepalive<br />
Retry Times<br />
Packet Size<br />
Serial Frame<br />
Interval<br />
Reconnect<br />
Interval<br />
Specific<br />
Protocol<br />
Heartbeat<br />
Interval<br />
ID<br />
Register<br />
String<br />
Server<br />
Address<br />
After TCP client is connected with TCP server, the client<br />
will send heartbeat packet by TCP regularly to keep alive.<br />
The interval range is 1-3600, in seconds.<br />
When TCP heartbeat times out, the router will resend<br />
heartbeat. After it reaches the preset retry times, router<br />
will reconnect to TCP server. The range is 1-16.<br />
Set the size of the serial data frame. Packet will be sent<br />
out when preset frame size is reached. The range is<br />
1-1024. The unit is byte.<br />
The interval that the router sends out real serial data<br />
stored in the buffer area to public network. The range is<br />
10-65535, in milliseconds.<br />
Note: data will be sent out to public network when real<br />
serial data size reaches the preset packet size, even<br />
though it's within the serial frame interval.<br />
After connection failure, router will reconnect to the<br />
server at the preset interval, in seconds. The range is<br />
10-60.<br />
By Specific Protocol, the router will be able to connect to<br />
the TCP2COM software.<br />
By Specific Protocol, the router will send heartbeat<br />
packet to the server regularly to keep alive. The interval<br />
range is 1-3600, in seconds.<br />
Define unique ID of each router. No longer than 63<br />
characters without space character.<br />
Define register string for connection with the server.<br />
Fill in the TCP or UDP server address (IP/domain name).<br />
Server Port Fill in the TCP or UDP server port. Range: 1-65535. Null<br />
Status<br />
Modbus<br />
Show the connection status between the router and the<br />
server.<br />
Local Port Set the router listening port. Range: 1-65535. 502<br />
Table 4-4-1-3 DTU Parameters<br />
75<br />
9<br />
1024<br />
100<br />
10<br />
--<br />
30<br />
--<br />
Null<br />
Null<br />
--<br />
Related Configuration Example<br />
DTU Application Example<br />
88