6: Integrated Diagnostics - Scan / Gas<br />

The Integrated Diagnostics - Scan / Gas function lets<br />

you views sensor and switch live data readings on<br />

the same screen as exhaust gas readings (CO, CO2,<br />

HC, O2, NOX AFR).<br />

NOTE: The Integrated Diagnostics option works only if<br />

the Gas M-P application is unlocked with a Smart Card<br />

and the Gas M-P hardware is used. For details, refer to the<br />

Gas M-P <strong>User</strong> <strong>Guide</strong>.<br />

To use the integrated diagnostics function,<br />

follow these steps:<br />

1 Follow the instructions in Test Startup and Vehicle<br />

Connection on page 14 to display the Diagnostic<br />

Menu screen.<br />

Figure 6.1: Diagnostic Menu Screen<br />

2 Select Integrated Diagnostics - Scan / Gas and<br />

press the ENTER key.<br />

3 Select a data group for viewing and press the ENTER<br />

key. This displays the Begin Zero screen.<br />

Figure 6.2: Begin Zero Screen<br />

4 Follow the instructions on the screen and then press<br />

the OK function key. This “zeros” the gas module and<br />

then displays the live data readings (Figure 6.3).<br />

Figure 6.3: Gas and Data Display<br />

5 Do the following to shift the gas data readings to<br />

match the datastream readings:<br />

NOTE: Because of the length of the vehicle<br />

exhaust system (engine to tail pipe), the exhaust<br />

gas produced in the engine at the time the data<br />

sensors read data is not measured until 9 to 14<br />

seconds later when the exhaust gas reaches the<br />

probe that is inserted in the tail pipe. Shifting the<br />

readings puts a time delay on the sensor datastream<br />

readings so they match the gas readings.<br />

a “Snap” the throttle open 2 or 3 times to set a full<br />

rich condition, count the number of seconds for<br />

the HC gas value to show the rich condition.<br />

Figure 6.4: More Function Key, Gas Options<br />

b On the scan tool, press the More function key,<br />

use the Direction key to select Gas Options,<br />

and press the ENTER key. This displays the<br />

Gas Correlation Time Shift screen (Figure 6.5<br />

on page 36).<br />

Scan Tool <strong>User</strong> <strong>Guide</strong> 35