15: System Setup<br />

Unit Defaults<br />

Unit Defaults<br />

The Unit Defaults function lets you set the date, time,<br />

units-of-measure, and automatic shut down time. It<br />

also lets you turn the audible beep and print header<br />

functions on or off.<br />

1 Follow the steps in Basic Procedure on page 69 to<br />

display the System Setup screen (see Figure 15.1).<br />

2 Select Unit Defaults and press the ENTER key.<br />

Figure 15.9: Unit Defaults Screen<br />

3 Use the Up and Down Direction keys to select the<br />

item to set from the far left column:<br />

Date— sets the date in the scan tool as month,<br />

date, and year.<br />

Time— sets the time in the scan tool as hours,<br />

minutes, and seconds (24 hour clock).<br />

Units — sets the units-of-measure as English<br />

or Metric.<br />

Auto Shutdown — sets the amount of time the<br />

scan tool stays on before shutting off automatically<br />

(only when using internal battery power).<br />

This is the amount of time since the last key<br />

press. The setting can be made for between<br />

5 and 60 minutes, in 5 minute increments.<br />

Beep — turns the audible beep on or off.<br />

Print Header— turns the print header function<br />

on or off. Refer to Printer Header on page 71.<br />

4 Press the Right Direction key once to move to the<br />

edit box.<br />

5 Use the Up or Down Direction key to select an option<br />

for the box.<br />

6 For Date and Time, repeat steps 4 and 5 to enter the<br />

entire date or time.<br />

7 Use the Left Direction key to go to the far left column.<br />

8 Repeat steps 3 through 7 until all the settings are<br />

made.<br />

9 Use the EXIT key to return to previous screens.<br />

Revision Levels<br />

The Revision Levels function displays software<br />

version numbers (for use when calling technical<br />

support).<br />

1 Follow the steps in Basic Procedure on page 69 to<br />

display the System Setup screen (see Figure 15.1).<br />

2 Select Revision Levels and press the ENTER key.<br />

Figure 15.10: Revision Levels Screen<br />

3 View the information.<br />

4 Use the EXIT key to return to previous screens.<br />

Dial-Up Settings<br />

The Dial-Up Settings function lets you set up<br />

IP addresses for communications (wired or wireless)<br />

between the scan tool and a PC or external device.<br />

1 Follow the steps in Basic Procedure on page 69 to<br />

display the System Setup screen (see Figure 15.1).<br />

2 Select Dial-Up Settings and press the ENTER key.<br />

Figure 15.11: Dial-Up Settings Screens<br />

3 On each screen that appears, select a dial up number<br />

or IP Address to edit and press the ENTER key.<br />

NOTE: Select an IP Address that is not in use by<br />

your network or another scan tool. If you are using<br />

multiple scan tools, use a different IP Address for<br />

each tool.<br />

4 When finished, use the EXIT key to return to previous<br />

screens.<br />

72 Scan Tool <strong>User</strong> <strong>Guide</strong>