MPS <strong>30</strong> User’s Manual DMMC/0803/CM<br />
• The numeric keys (0–9/F0–9) to <strong>set</strong> the desired values of the controlled<br />
parameters when used with RED or BLUE SHIFT functions, F0–F9.<br />
(Note: Some of the “F” legends on the upper position of the numeric keys<br />
are not used and can be programmed for custom requirements.)<br />
• The UP triangle key (▲) to increase, by a pre-programmed step, the<br />
different parameters (AL, AS, and AR).<br />
• The DOWN triangle key (▼) to decrease, by a pre-programmed step, the<br />
different parameters (AL, AS, and AR).<br />
• The PROG/EXEC/DEFAULT key for programming functions. PROGram is<br />
used for entering the programming mode, EXECute to initiate the<br />
program, and DEFAULT for returning to the operational mode.<br />
• The AL, AS, AR (UP/DOWN ARROW) key is used before the previous<br />
key to establish the parameter that must be changed.<br />
• The BLUE SHIFT key ( ) to activate the upper-left functions on the keys,<br />
marked in blue.<br />
• The RED SHIFT key ( ) to activate the upper-right functions on the keys,<br />
marked in red.<br />
• The GO/ENTER key (↵) to input the desired <strong>data</strong> to the MPS <strong>30</strong>.<br />
• The EPR/NOR key to generate a total pressure/static pressure ratio<br />
starting from the desired altitude. The blue upper-left NOR on this key is<br />
used to re<strong>set</strong> the NORmal <strong>air</strong> <strong>data</strong> operation, when used with BLUE<br />
SHIFT.<br />
Issue Aug. 03 D. Marchiori PROPRIETARY INFORMATION - 16<br />