MPS <strong>30</strong> User’s Manual DMMC/0803/CM<br />

NOTE 2<br />

The Airspeed is <strong>set</strong> up to 100 Kts. for every<br />

<strong>test</strong> point because the <strong>test</strong> is related to the<br />

static system. Also ZERO Kts could be <strong>set</strong><br />

up for the Airspeed (except points A and B<br />

of TABLE 2). If the Airspeed indicator must<br />

be checked, different Airspeed <strong>data</strong> can be<br />

commanded. The <strong>air</strong>speed instrument is<br />

better <strong>test</strong>ed leaving the <strong>air</strong>craft or the<br />

instrument static port in ambient (thus<br />

leaving in ambient also the MPS<strong>30</strong> static<br />

port and <strong>set</strong>ting its AR = 0, this removes the<br />

control of the static pressure)<br />

step Alt Asp Rate Rate Wait L0 L1<br />

A 500 100 0 <strong>30</strong>0 0 60 <strong>30</strong><br />

B 5000 100 <strong>30</strong>00 <strong>30</strong>0 0 60 <strong>30</strong><br />

C -1000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

D 0 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

E 500 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

F 1000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

G 1500 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

H 2000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

I <strong>30</strong>00 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

J 4000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

K 6000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

L 8000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

M 10000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

N 12000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

O 14000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

P 16000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

Q 18000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

R 20000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

S 22000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

T 25000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

U <strong>30</strong>000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

V 35000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

W 40000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

X 45000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

Y 50000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />

TABLE 2<br />

Issue Aug. 03 D. Marchiori PROPRIETARY INFORMATION - 38<br />