MPS <strong>30</strong> User’s Manual DMMC/0803/CM<br />
NOTE 2<br />
The Airspeed is <strong>set</strong> up to 100 Kts. for every<br />
<strong>test</strong> point because the <strong>test</strong> is related to the<br />
static system. Also ZERO Kts could be <strong>set</strong><br />
up for the Airspeed (except points A and B<br />
of TABLE 2). If the Airspeed indicator must<br />
be checked, different Airspeed <strong>data</strong> can be<br />
commanded. The <strong>air</strong>speed instrument is<br />
better <strong>test</strong>ed leaving the <strong>air</strong>craft or the<br />
instrument static port in ambient (thus<br />
leaving in ambient also the MPS<strong>30</strong> static<br />
port and <strong>set</strong>ting its AR = 0, this removes the<br />
control of the static pressure)<br />
step Alt Asp Rate Rate Wait L0 L1<br />
A 500 100 0 <strong>30</strong>0 0 60 <strong>30</strong><br />
B 5000 100 <strong>30</strong>00 <strong>30</strong>0 0 60 <strong>30</strong><br />
C -1000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
D 0 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
E 500 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
F 1000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
G 1500 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
H 2000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
I <strong>30</strong>00 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
J 4000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
K 6000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
L 8000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
M 10000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
N 12000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
O 14000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
P 16000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
Q 18000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
R 20000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
S 22000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
T 25000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
U <strong>30</strong>000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
V 35000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
W 40000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
X 45000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
Y 50000 100 <strong>30</strong>00 <strong>30</strong>0 90 0 0<br />
TABLE 2<br />
Issue Aug. 03 D. Marchiori PROPRIETARY INFORMATION - 38<br />