06.01.2013 Views

air data test set mps 30 digital portable user manual - CALIBRATION ...

air data test set mps 30 digital portable user manual - CALIBRATION ...

air data test set mps 30 digital portable user manual - CALIBRATION ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

READ<br />

SET<br />

PRESS<br />

READ<br />

SET<br />

PRESS<br />

8.8 Mach Number<br />

MPS <strong>30</strong> User’s Manual DMMC/0803/CM<br />

ALTITUDE AIRSPEED RATE<br />

ENG. PRESS. RATIO<br />

Pst:<br />

EPR:<br />

Pt/Ps MACH UNITS<br />

HHRCU in EPR input mode<br />

Figure 8-4 HHRCU in EPR Input Mode<br />

ALTITUDE AIRSPEED RATE<br />

26275 321.8 0<br />

26274 EPR 6000<br />

10.500 5.250 15.750<br />

1.500 0.784 Ft Kt in<br />

Pt/Ps MACH UNITS<br />

Figure 8-5 HHRCU in EPR Control Mode<br />

READ<br />

SET<br />

PRESS<br />

READ<br />

SET<br />

PRESS<br />

Instead of an <strong>air</strong>speed value, the Mach Number can be entered as a control<br />

parameter. The procedure is the following: press BLUE SHIFT then the F0 (also the<br />

0, or zero key). After input of the desired Mach number, press RETURN/GO. The<br />

<strong>air</strong>speed corresponding to this Mach number at the previously <strong>set</strong> altitude is now<br />

shown in the SET line of the <strong>air</strong>speed.<br />

Issue Aug. 03 D. Marchiori PROPRIETARY INFORMATION - 28<br />

This material not to be disclosed or reproduced.