D CDA3000 Inverter Drive System 750 W - 132 kW - Igor Chudov
D CDA3000 Inverter Drive System 750 W - 132 kW - Igor Chudov
D CDA3000 Inverter Drive System 750 W - 132 kW - Igor Chudov
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
2.3 Wall mounting<br />
BG6<br />
<strong>CDA3000</strong> Operation Manual<br />
2 Mechanical installation<br />
Step Action Comment<br />
1<br />
2<br />
3<br />
4<br />
Mark out the position of the tapped holes<br />
on the backing plate.<br />
Cut a tap for each fixing screw in the<br />
backing plate.<br />
Mount the inverter module vertically on<br />
the backing plate.<br />
Mount the other components, such as the<br />
mains filter, line choke etc., on the<br />
backing plate.<br />
Continue with the electrical installation in<br />
section 3.<br />
F<br />
;;; yyy;;<br />
yy<br />
F<br />
UM-xxxx<br />
Figure 2.1 Mounting clearances (see Table 2.2)<br />
Note the following points:<br />
E<br />
CM-xxxx<br />
E1<br />
2-2<br />
Dimensional drawings/hole<br />
spacing see Table 2.2.<br />
The tapping area will provide<br />
you with good, full-area contact.<br />
Pay attention to the mounting<br />
clearances!<br />
The contact surface must be<br />
metallically bright.<br />
Mains filter max. 20 cm below<br />
the inverter module<br />
;;; yyy ; y ; y;;<br />
yy;<br />
y<br />
; y ; y ; y<br />
; y ; y ; y<br />
Air must be able to flow unhindered through the device.<br />
For mounting in switch cabinets with convection (= heat loss is<br />
discharged to the outside via the cabinet walls) an internal air<br />
circulation fan must always be fitted.<br />
The backing plate must be well grounded.<br />
The best result for effective EMC installation is attained with a<br />
chromated or galvanized backing plate. If backing plates are<br />
varnished, the coating must be removed in the area of the contact<br />
surface!<br />
G