<strong>CDA3000</strong> Operation Manual<br />

Mains load (example)<br />

Mains voltage asymmetry (example)<br />

Without line choke With line choke Change<br />

4 <strong>kW</strong> inverter,<br />

mains impedance<br />

0.6 mH<br />

Recommended:<br />

The example shows that the benefits of a line choke with 4 % short-circuit<br />

voltage are multi-faceted. We therefore recommend that you use a line<br />

choke as a matter of course.<br />

A-13<br />

4 <strong>kW</strong> inverter,<br />

mains impedance<br />

6mH<br />

Without line choke<br />

compared to<br />

with line choke<br />

Voltage distortion (THD) 1) 99 % 33 % -67 %<br />

Mains current amplitude 18.9 A 9.7 A -48 %<br />

Mains current effective<br />

Commutation notches<br />

8.5 A 6.23 A -27 %<br />

referred to the mains<br />

voltage<br />

28 V 8 V -70%<br />

Life of the DC-link<br />

capacitors<br />

Nominal life<br />

2 to 3 times<br />

nominal life<br />

+100 to 200 %<br />

1) THD = Total Harmonic Distortion (U 5 ...U 41 )<br />

Table A.1 Change in system load resulting from insertion of a line choke<br />

with 4% short-circuit voltage based on the example of a 4 <strong>kW</strong><br />

inverter CDA34.010<br />

Without line choke With line choke<br />

4 <strong>kW</strong> inverter, mains<br />

impedance 0.6 mH<br />

4 <strong>kW</strong> inverter, mains<br />

impedance 6 mH<br />

Asymmetry of mains<br />

voltage<br />

0 % +3 % -3 % 0 % +3 % -3 %<br />

Mains current amplitude 18.9 A 25.4 A 25.1 A 9.7 A 10.7 A 11 A<br />

Mains current effective 8.5 A 10.5 A 10.2 A 6.2 A 6.7 A 6.8 A<br />

Table A.2 Effect of the line choke with asymmetrical mains voltage<br />

based on the example of a 4 <strong>kW</strong> inverter CDA34.010<br />

1<br />

2<br />

3<br />

4<br />

5<br />

A<br />

DE<br />