3.8 Control<br />
connections<br />
<strong>CDA3000</strong> Operation Manual<br />
3 Installation<br />
Step Action Comment<br />
1<br />
2<br />
Check whether your inverter module is<br />
fitted<br />
a modified software package<br />
(>V100.x)<br />
(standard software = Vx.xx-xx)<br />
If this is the case, the control terminal<br />
assignment is different. Please<br />
contact your project engineer with<br />
regard to wiring and commissioning!!<br />
Check whether you already have a<br />
SMARTCARD or a DRIVEMANAGER data<br />
set with a complete device setup.<br />
If this is the case, the control terminal<br />
assignment is different. Please<br />
contact your project engineer to obtain<br />
the terminal assignment!<br />
3 Choose a terminal assignment.<br />
4<br />
5<br />
Wire the control terminals with<br />
shielded cables.<br />
The only essential signals are the<br />
ENPO signals and a start signal<br />
(STR or STL).<br />
Keep all contacts open<br />
(inputs inactive).<br />
6 Check all connections again!<br />
Note the following points:<br />
3-13<br />
ANTRIEBSTECHNIK<br />
D- 35633 Lahnau<br />
Position of software name plate see<br />
section 3.1 Page 3-2<br />
Bulk customers<br />
Type: CDA32.004,C1.0<br />
Software: V 1xx.x<br />
CS:<br />
Data Set:<br />
C1D1<br />
SN.: 99120442<br />
For details of how to load the data<br />
set into the inverter module refer to<br />
section 4.6.<br />
see 3.8.1 “Choice of terminal<br />
assignment”<br />
Ground the cable shields over a<br />
wide area at both ends.<br />
Wire cross-section maximum<br />
1.5 mm² or two cores per terminal<br />
each 0.5 mm²<br />
Continue with commissioning in<br />
section 4.<br />
Always wire the control terminals with shielded cables.<br />
Lay the control cables separately from the mains lead and motor<br />
cable.<br />
The <strong>CDA3000</strong> Application Manual presents more drive solutions.<br />
For all shielded connections a cable type with double copper<br />
braiding with 60-70 % coverage must be used.<br />