D CDA3000 Inverter Drive System 750 W - 132 kW - Igor Chudov
D CDA3000 Inverter Drive System 750 W - 132 kW - Igor Chudov
D CDA3000 Inverter Drive System 750 W - 132 kW - Igor Chudov
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
1. Preset solution...<br />
2. Control method...<br />
<strong>CDA3000</strong> Operation Manual<br />
In this window you<br />
select the terminal<br />
assignment required<br />
for control of your<br />
application.<br />
As a check, the<br />
terminal diagram and<br />
specimen<br />
applications are<br />
illustrated.<br />
For our example<br />
please set ROT_2.<br />
4 Commissioning<br />
Different control methods have special advantages depending on the<br />
application. Three modes of control are available.<br />
For our example please set FOR(2).<br />
VFC<br />
SFC<br />
FOR<br />
Meaning Application<br />
Voltage Frequency Control<br />
(factory setting)<br />
Sensorless Flux Control<br />
Only for asynchronous<br />
motors<br />
Field Oriented Regulation<br />
Encoder is necessary<br />
only for asynchronous<br />
motors<br />
Table 4.2 Choice of control method<br />
4-7<br />
Pump, fan and extruder applications<br />
Traction and lifting drive with low dynamics<br />
Multi-motor operation<br />
Dynamic traction, lifting and rotational<br />
drives<br />
<strong>Drive</strong>s with dynamic load surges<br />
Dynamic traction and rotational drives<br />
Speed control with encoder feedback<br />
1<br />
2<br />
3<br />
4<br />
5<br />
A<br />
DE<br />
EN<br />
FR<br />
IT<br />
ES<br />
FR