1. Preset solution...<br />

2. Control method...<br />

<strong>CDA3000</strong> Operation Manual<br />

In this window you<br />

select the terminal<br />

assignment required<br />

for control of your<br />

application.<br />

As a check, the<br />

terminal diagram and<br />

specimen<br />

applications are<br />

illustrated.<br />

For our example<br />

please set ROT_2.<br />

4 Commissioning<br />

Different control methods have special advantages depending on the<br />

application. Three modes of control are available.<br />

For our example please set FOR(2).<br />

VFC<br />

SFC<br />

FOR<br />

Meaning Application<br />

Voltage Frequency Control<br />

(factory setting)<br />

Sensorless Flux Control<br />

Only for asynchronous<br />

motors<br />

Field Oriented Regulation<br />

Encoder is necessary<br />

only for asynchronous<br />

motors<br />

Table 4.2 Choice of control method<br />

4-7<br />

Pump, fan and extruder applications<br />

Traction and lifting drive with low dynamics<br />

Multi-motor operation<br />

Dynamic traction, lifting and rotational<br />

drives<br />

<strong>Drive</strong>s with dynamic load surges<br />

Dynamic traction and rotational drives<br />

Speed control with encoder feedback<br />