4.9 Parameter list<br />

(selection)<br />

Any parameters can be<br />

inserted into this<br />

subject area using the<br />

DRIVEMANAGER (V3.0 or<br />

higher). The number is<br />

limited to 14. *<br />

In the factory setting<br />

the parameters listed<br />

here are inserted.<br />

* For more information<br />

refer to the DRIVEMANAGER<br />

MANUAL.<br />

<strong>CDA3000</strong> Operation Manual<br />

4 Commissioning<br />

Name Unit Function<br />

4-19<br />

Factory<br />

setting<br />

Subject area User-defined_11UA<br />

01-MODE - User level of KP200 2<br />

150-SAVE - Save setting in device READY<br />

152 -ASTER - Preset terminal assignment DRV_1<br />

180 -FISA0 - Function selector of ISA00 off<br />

181 -FISA1 - Function selector of ISA01 off<br />

242 -FOS02 - Function selector of OSD02 off<br />

270-FFIX1 Hz<br />

Fixed frequency characteristic data<br />

set CDS1<br />

20<br />

301 -FMIN1 Hz CDS1: Minimum frequency 0<br />

303 -FMAX1 Hz CDS1: Maximum frequency 50<br />

330-MOPTC - Type of PTC evaluation off<br />

590 -ACCR1 Hz/s CDS1: Acceleration ramp 20<br />

592 -DECR1 Hz/s CDS1: Braking ramp 20<br />

594 -STPR1 Hz/s CDS1: Stop ramp 20<br />

95-ERR1 h Last error -<br />

Subject area Initial commissioning _15FC<br />

150-SAVE - Back-up device setup READY<br />

152 -ASTER - Preset terminal assignment DRV_1<br />

Subject area Fixed frequencies_27FF<br />

270-FFIX1 Hz Fixed frequency 20<br />

Subject area Frequency limits_30OL<br />

301 -FMIN1 Hz CDS1: Minimum frequency 0<br />

303 -FMAX1 Hz CDS1: Maximum frequency 50<br />

Subject area Motor protection _33MO<br />

330-MOPTC - Type of motor PTC evaluation OFF<br />

Subject area Driving profile generator _59DP<br />

590 -ACCR1 Hz/s CDS1: Acceleration ramp 20<br />

592 -DECR1 Hz/s CDS1: Deceleration ramp 20<br />

594 -STPR1 Hz/s CDS1: Stop ramp 20<br />

Subject area Encoder evaluation _79EN<br />

790-ECLNC<br />

Pulses<br />

per rev<br />

Lines per revolution of encoder 1024<br />

Your<br />

setting<br />

1<br />

2<br />

3<br />

4<br />

5<br />

A<br />

DE<br />

EN<br />

FR<br />

IT<br />

ES<br />

FR