A.3 Ambient<br />
conditions<br />
<strong>CDA3000</strong> Operation Manual<br />
Characteristic <strong>Inverter</strong> module<br />
Temperature<br />
range<br />
in operation<br />
in storage -25 ... +55 °C<br />
in transit -25 ... +70 °C<br />
-10 ...45 ° C (BG1 ... BG5)<br />
0 ... 40 ° C (BG6 ... BG8)<br />
with power reduction to 55 ° C<br />
Relative air humidity 15 ... 85 %, condensation not permitted<br />
Mechanical<br />
strength to<br />
IEC 68-2-6<br />
Protection<br />
in stationary<br />
use<br />
in transit<br />
Device IP20 (NEMA 1)<br />
Cooling<br />
method<br />
Touch protection VBG 4<br />
Mounting height<br />
Voltage stress of the<br />
motor winding<br />
Vibration: 0.075 mm in frequency range 10 ... 58 Hz<br />
Shock: 9.8 m/s 2 in frequency range >58 ... 500 Hz<br />
Vibration: 3.5 mm in frequency range 5 ... 9 Hz<br />
Shock: 9.8 m/s 2 in frequency range >9 ... 500 Hz<br />
Cold plate: IP20<br />
Push-through heat sink: IP54 (3 ...15 <strong>kW</strong>)<br />
up to 1000 m above MSL, above 1000 m above MSL<br />
with power reduction 1% per 100 m, max. 2000 m<br />
above MSL<br />
typical slew rate 3 - 6 kV/µs<br />
Note: If a rotating field frequency of > 200/400 Hz is required,<br />
inverter modules with special firmware for high-frequency<br />
motors must be ordered. Detailed order data see in order<br />
catalogue <strong>CDA3000</strong>.<br />
A-8