4.5 Direction check Precondition:<br />
1. Test phase position of motor<br />
connections.<br />
(1)<br />
2. Test encoder connection Precondition:<br />
R<br />
L<br />
(2)<br />
<strong>CDA3000</strong> Operation Manual<br />
4 Commissioning<br />
<strong>Inverter</strong> module is fully connected.<br />
The motor planned for the application is correctly connected.<br />
Device set to VFC mode = Voltage Frequency Control (factory<br />
setting).<br />
Enter a low reference value, e.g. slow jog.<br />
Step Action Note<br />
1 Close ENPO contact. ENPO active enables power stage.<br />
2<br />
Start drive by closing STR<br />
contact.<br />
Motor accelerates to preset reference<br />
3<br />
Check direction of rotation of<br />
drive.<br />
With STR active, motor rotates<br />
clockwise (2)<br />
(1) Direction of view.<br />
4<br />
Brake drive by opening start<br />
contact.<br />
<strong>Drive</strong> brakes down to standstill.<br />
5 Open ENPO contact.<br />
ENPO inactive safely disables power<br />
stage.<br />
6<br />
If direction is wrong, check phase<br />
position of motor connections.<br />
Also check the control connections:<br />
STR > term. X2/9 (ISD00)<br />
If the direction matches the actuation, the test is completed.<br />
<strong>Inverter</strong> module is fully connected.<br />
The motor with encoder planned for the application is correctly<br />
connected.<br />
Device set to FOR mode = Field Oriented Regulation.<br />
Step Action Note<br />
1 Open ENPO contact. Power stage safely disabled.<br />
Turn motor shaft clockwise by hand In status display:<br />
2<br />
(1) Direction of view, (2) Clockwise. Right (clockwise) = no preceding sign<br />
Left (anti-clockwise) = neg. preceding<br />
sign.<br />
3<br />
If assignment is wrong, check wiring<br />
of encoder.<br />
If the direction matches the display, the test is completed.<br />
4-11<br />
1<br />
2<br />
3<br />
4<br />
5<br />
A<br />
DE<br />
EN<br />
FR<br />
IT<br />
ES<br />
FR