4.5 Direction check Precondition:<br />

1. Test phase position of motor<br />

connections.<br />

(1)<br />

2. Test encoder connection Precondition:<br />

R<br />

L<br />

(2)<br />

<strong>CDA3000</strong> Operation Manual<br />

4 Commissioning<br />

<strong>Inverter</strong> module is fully connected.<br />

The motor planned for the application is correctly connected.<br />

Device set to VFC mode = Voltage Frequency Control (factory<br />

setting).<br />

Enter a low reference value, e.g. slow jog.<br />

Step Action Note<br />

1 Close ENPO contact. ENPO active enables power stage.<br />

2<br />

Start drive by closing STR<br />

contact.<br />

Motor accelerates to preset reference<br />

3<br />

Check direction of rotation of<br />

drive.<br />

With STR active, motor rotates<br />

clockwise (2)<br />

(1) Direction of view.<br />

4<br />

Brake drive by opening start<br />

contact.<br />

<strong>Drive</strong> brakes down to standstill.<br />

5 Open ENPO contact.<br />

ENPO inactive safely disables power<br />

stage.<br />

6<br />

If direction is wrong, check phase<br />

position of motor connections.<br />

Also check the control connections:<br />

STR > term. X2/9 (ISD00)<br />

If the direction matches the actuation, the test is completed.<br />

<strong>Inverter</strong> module is fully connected.<br />

The motor with encoder planned for the application is correctly<br />

connected.<br />

Device set to FOR mode = Field Oriented Regulation.<br />

Step Action Note<br />

1 Open ENPO contact. Power stage safely disabled.<br />

Turn motor shaft clockwise by hand In status display:<br />

2<br />

(1) Direction of view, (2) Clockwise. Right (clockwise) = no preceding sign<br />

Left (anti-clockwise) = neg. preceding<br />

sign.<br />

3<br />

If assignment is wrong, check wiring<br />

of encoder.<br />

If the direction matches the display, the test is completed.<br />