3. Motor data...<br />

<strong>CDA3000</strong> Operation Manual<br />

4 Commissioning<br />

By way of the automatic motor identification the characteristic data of IEC<br />

standard motors and ASM servomotors can be determined. The<br />

precondition for problem-free identification is that the rating plate data are<br />

present and correctly entered.<br />

Note: The data of the motor nominal point (max. rated power output<br />

of the motor) must always be entered. In 87 Hz applications<br />

(motor: 230 V, delta configuration) the converted 87 Hz data<br />

must be entered. For more information refer to the <strong>CDA3000</strong><br />

Application Manual.<br />

For our example this setting is required.<br />

Following identification of the motor, all control loops are automatically<br />

computed and the necessary parameter adjustments made.<br />

Precondition:<br />

The motor is connected.<br />

Hardware enabled ( = ENPO contact closed).<br />

1<br />

3<br />

2<br />

Step Action Note<br />

1 Enter motor data see your motor type designation<br />

2 Click on “Start identification” button Takes approx. 3 min.<br />

3 Apply setting Values are transferred to device<br />

4 Re-open ENPO contact on device<br />

Motor identification is complete<br />

Power stage safely disabled<br />

4-8