KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />

D-SUB connector<br />

at X2B<br />

1<br />

8<br />

9<br />

15<br />

Male<br />

connector<br />

Connector<br />

housing<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

Output of the incremental<br />

encoder with serial interface at<br />

the motor<br />

Figure 28: Pin assignment: Digital incremental encoder - option [X2B]<br />

TEMP-<br />

TEMP+<br />

SENSE+<br />

SENSE-<br />

Shield (optional)<br />

Connector housing<br />

E 732 GB 101<br />

14.12.2006<br />

VCC<br />

GND<br />

N<br />

N#<br />

HALL_U<br />

HALL_V<br />

HALL_W<br />

8.10 Connection: Incremental encoder input [X10]<br />

8.10.1 Configuration on the device [X10]<br />

� D-SUB connector, 9-pin type, female<br />

8.10.2 Mating connector [X10]<br />

� D-SUB connector, 9-pin type, male<br />

� Housing for 9-pin D-SUB connector with bolting screws of type 4/40 UNC<br />

A<br />

A#<br />

B<br />

B#