8.4.3 Pin assignment [X9] at the <strong>ARS</strong> <strong>2340</strong><br />
Table 29: Pin assignment [X9] at the <strong>ARS</strong> <strong>2340</strong>: Supply<br />
Pin no. Name Value Specification<br />
1 L1 3 x 230 VAC -10% Supply: Mains phase L1<br />
2 L2 to<br />
Supply: Mains phase L2<br />
3 L3<br />
3 x 480 VAC +10% Supply: Mains phase L2<br />
4 PE - Connection of mains ground conductor<br />
5<br />
6<br />
7<br />
8<br />
ZK+ < 700 VDC Alternative supply: Positive DC-link voltage<br />
ZK- < 700 VDC Alternative supply: Negative DC-link voltage<br />
8.4.4 Type and configuration of cable [X9] at the <strong>ARS</strong> <strong>2340</strong><br />
The cable names given refer to cables made by Lapp. They have proven to be reliable and are<br />
successfully used in many applications. However, it is also possible to use comparable cables from<br />
other manufacturers, e.g. Lütze or Helukabel.<br />
For 400 VAC supply:<br />
� LAPP KABEL ÖLFLEX-CLASSIC 110; 4 x 6 mm²<br />
8.4.5 Connection notes concerning [X9] at the <strong>ARS</strong> <strong>2340</strong><br />
Power supply connector<br />
L1<br />
L2<br />
L3<br />
PE<br />
ZK+<br />
ZK+ 6<br />
ZK-<br />
ZK-<br />
Figure 19: Pin assignment [X9] at the <strong>ARS</strong> <strong>2340</strong>: Supply<br />
PHOENIX Power-<br />
Combicon at X9<br />
82 E 732 GB<br />
14.12.2006<br />
1<br />
2<br />
3<br />
4<br />
5<br />
7<br />
8