KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />
8.5.3 Pin assignment [X3]<br />
Table 31: Pin assignment [X3]<br />
Pin<br />
no.<br />
Name Value Specification<br />
1 24V 24VDC / 2.8 A 24VDC supply for control section (0.8A) and holding brake<br />
(2A)<br />
(Without safety measures in accordance with category 3: Bridge<br />
pin 1 and 2)<br />
2 REL 0VDC / 24VDC Setting and resetting of the relay for interrupting the driver<br />
supply<br />
3 0V GND 24 VDC Reference potential for the 24VDC supply and the PLC<br />
4 ERR 0V / 24VDC Signaling contact "Error on safety module"<br />
5 NC1<br />
6 NC2<br />
250VAC max.<br />
switching<br />
voltage<br />
Floating response contact of driver supply, normally closed<br />
contact<br />
8.5.4 Cable type and configuration: 24VDC power supply [X3]<br />
The cable names given refer to cables made by Lapp. They have proven to be reliable and are<br />
successfully used in many applications. However, it is also possible to use comparable cables from<br />
other manufacturers, e.g. Lütze or Helukabel.<br />
For 24 VAC power supply:<br />
� LAPP KABEL ÖLFLEX-CLASSIC 110; 2 x 1 mm²<br />
8.5.5 Connection notes [X3]<br />
Braking resistor<br />
connector<br />
24 VDC supply 1<br />
Without category 3 safety equipment:<br />
2<br />
Bridge between pin 1 and 2<br />
GND 24 VDC<br />
3<br />
4<br />
5<br />
6<br />
Figure 21: Pin assignment [X3]: 24VDC power supply<br />
PHOENIX MINI<br />
COMBICON at X3<br />
E 732 GB 85<br />
14.12.2006