Prior to accessing electrical parts carrying voltages exceeding 50 Volts, disconnect the<br />
device from the mains or power supply. Protect it from being switched on again.<br />
For the installation the amount of DC bus voltage must be considered, particularly<br />
regarding insulation and protective measures. Ensure proper grounding, wire<br />
dimensioning and corresponding short-circuit protection.<br />
The device comprises a rapid discharge circuit for the DC bus as per EN60204 section<br />
6.2.4. In certain device constellations, however, mostly in the case of parallel connection<br />
of several servo drive controllers in the DC bus or in the case of an unconnected brake<br />
resistor, this rapid discharge may be rendered ineffective. The servo drive controllers<br />
can carry voltage until up to 5 minutes after being switched off (residual capacitor<br />
charge).<br />
2.4.4 Protection against electrical shock by means of protective extra-low<br />
voltage (PELV)<br />
All connections and terminals with voltages between 5 and 50 Volts at the servo drive controller are<br />
protective extra-low voltage, which are designed safe from contact in correspondence with the<br />
following standards:<br />
International: IEC 60364-4-41<br />
European countries within the EU: EN 50178/1998, section 5.2.8.1.<br />
DANGER!<br />
High electrical voltages due to wrong connections!<br />
Danger to life, risk of injury due to electrical shock!<br />
Only devices and electrical components and wires with a protective extra low voltage (PELV) may be<br />
connected to connectors and terminals with voltages between 0 to 50 Volts.<br />
Only connect voltages and circuits with protection against dangerous voltages. Such protection may<br />
be achieved by means of isolation transformers, safe optocouplers or battery operation.<br />
2.4.5 Protection against dangerous movements<br />
Dangerous movements can be caused by faulty control of connected motors, for different reasons:<br />
� Improper or faulty wiring or cabling<br />
� Error in handling of components<br />
� Error in sensor or transducer<br />
� Defective or non-EMC-compliant components<br />