5.3.7 Optional stop input<br />
The optional stop input can interrupt the running positioning process by setting the adjusted digital<br />
input. When the digital input is reset, the positioning process continues to approach to original target<br />
position. Since the existing digital inputs are usually occupied by standard applications, the analog<br />
inputs AIN1 and AIN2 as well as the digital outputs DOUT2 and DOUT3, which can also be used as<br />
digital inputs, can be used as an option.<br />
5.3.8 Continuous-path control with linear interpolation<br />
Due to the implementation of the interpolated position mode, position setpoints can be set for multiaxis<br />
use of the controller. In this mode, position setpoints are specified by a subordinated control at<br />
fixed intervals (synchronization intervals). If the interval is greater than a position controller cycle, the<br />
controller automatically interpolates the data values between two specified position values as shown<br />
in the following graph. In addition, the servo positioning controller also calculates a corresponding<br />
speed feedforward.<br />
y<br />
t: synchronisation interval<br />
s y n c<br />
t p<br />
t P<br />
: interpolation data<br />
: Position setpoint, internally<br />
: Position control / positioning cycle time<br />
: Interpolated course of position (setpoint)<br />
: Travelled course of position (actual value)<br />
Figure 7: Linear interpolation between two data values<br />
t P<br />
E 732 GB 53<br />
14.12.2006<br />
t