Fault Possible cause Remedy By whom<br />

Indicator Lamp<br />

"Fault" illuminates<br />

Message "Recycled<br />

water tank empty"<br />

displayed on washing<br />

system.<br />

The swimmer switch S4.2 has triggererd<br />

<strong>and</strong> S4.1 is not in the top position.<br />

Washing system runs with fresh water until level<br />

S4.1 top is reached. Find the cause.<br />

- 9<br />

Customer Service<br />

Float switch S4 in pump basin is defective. Repair or replace float switch. Customer Service<br />

Motor protection switch of the immersion<br />

pump has been triggered.<br />

Water level in the pump basin is too low <strong>and</strong><br />

emergency fresh water supply has failed<br />

Reset motor protection switch; call Customer Service<br />

if the problem recurs.<br />

Refill pump basin; check emergency fresh water<br />

supply; repair, if required.<br />

Operator<br />

Operator, Customer<br />

Service<br />

Float switch S11 is defective or loose Replace the float switch or reattach it Customer Service<br />

Immersion pump has failed, is dirty or defective<br />

Restart the plant by switching off <strong>and</strong> on; otherwise<br />

call Customer service<br />

Operator<br />

Pipe connections are leaky Check all pipe connections; seal them, if required Operator, Customer<br />

Service<br />

Controls are defective Check, repair or replace controls Customer Service<br />

Gravel filter plugged (filter output is too low) Backwash several times; if not successful, change<br />

the gravel<br />

Operator/Customer<br />

Service<br />

Multi-channel defective Repair multi-channel valve; replace defective parts Customer Service<br />

Plant out of order Power supply is interrupted Check power supply <strong>and</strong> ensure proper supply. Operator<br />

Controls are defective Check, repair or replace controls Customer Service<br />

Processed water is<br />

coloured or is foaming<br />

too much<br />

Water in the processed<br />

water tank has<br />

a bad odour<br />

Continuous flow<br />

sound<br />

Immersion pump is<br />

not functioning<br />

Filter output is too<br />

low<br />

Fresh water consumption<br />

is too high<br />

Sludge collector or pump basin is dirty Emptying <strong>and</strong> cleaning the basins Operator/ Disposal<br />

agency<br />

Improper detergents are used in the washing<br />

unit or washing hall<br />

Detergent dosing in the washing unit is too<br />

high<br />

Washing place cleaned with incompatible<br />

detergents<br />

<strong>WRP</strong> was switched off during the night or<br />

over the weekend<br />

none or very poor circulation, very little ventilation<br />

Float switch, control or fresh water solenoid<br />

valve defective<br />

Use compatible detergents; rinse the system, if<br />

necessary<br />

Operator, Customer<br />

Service<br />

Check detergent dosing; reset, if necessary Operator, Customer<br />

Service<br />

Replace water <strong>and</strong> rinse the basins Operator<br />

<strong>WRP</strong> must be ON continuously Operator<br />

Check whether the recirculation valve is open <strong>and</strong><br />

if the flow is at least 1.5 m 3 / (<strong>WRP</strong> 10,000) or 2.0<br />

m 3 /h (<strong>WRP</strong> 20,000).<br />

Check pipes for dirt <strong>and</strong> damage; clean or replace<br />

them as required<br />

Check the ventilation, the ventilator must clearly<br />

bubble in the pump basin.<br />

Operator<br />

Operator, Customer<br />

Service<br />

Customer Service<br />

Check, repair or replace the concerned component Operator, Customer<br />

Service<br />

Water level in the pump basis is too low Washing system runs with fresh water until level<br />

S4.1 top is reached. Find the cause.<br />

Float switch S7 defective Check the float switch; clean, repair or replace it as<br />

required<br />

Control head of multi-channel valve is defective<br />

Customer Service<br />

Operator, Customer<br />

Service<br />

Repair control head Customer Service<br />

Controls are defective Check, repair or replace controls Customer Service<br />

Gravel filter is blocked Backwash gravel filter or change the gravel. If the<br />

problem recurs, increase the backwash duration<br />

<strong>and</strong>/or increase the frequency.<br />

Operator, Customer<br />

Service<br />

Immersion pump is blocked, defective Clean, repair, replace immersion pump Operator, Customer<br />

Service<br />

Pipe or valve is leaky, defective, blocked Check pipes <strong>and</strong> valves; clean, repair or replace as<br />

required<br />

Operator, Customer<br />

Service<br />

Float switch S9 is defective. Replace Customer Service<br />

Conductivity sensor is defective or contaminated.<br />

EN<br />

Check; clean, replace, if required. Operator, Customer<br />

Service<br />