Accessories<br />

Filter gravel, fine<br />

Order No. 6.272-001.0 (Grain size 04,...0.8<br />

mm) in 25 kg sack<br />

Filter gravel, medium<br />

Order No. 6.272-003.0 (Grain size 1...2<br />

mm) in 25 kg sack<br />

Needed for one fiter filling<br />

<strong>WRP</strong><br />

<strong>10000</strong><br />

<strong>WRP</strong><br />

<strong>20000</strong><br />

Filter gravel,<br />

fine 6.272.-<br />

001.0<br />

7 sacks 2 sacks<br />

10 sacks 3 sacks<br />

Filter gravel, medium<br />

6.272.-<br />

003.0<br />

Accessories Order number<br />

Recycled water tank 2.641-981.0<br />

Additional tank 2.642-117.0<br />

Ventilation 2.641-510.0<br />

Overflow 2.641-995.0<br />

Immersion pump <strong>WRP</strong> 2.642-037.0<br />

<strong>10000</strong><br />

Immersion pump <strong>WRP</strong> 2.642-038.0<br />

<strong>20000</strong><br />

St<strong>and</strong> for switch cabi- 2.642-116.0<br />

net<br />

Conductivity measure- 2.641-996.0<br />

ment<br />

Fresh water supply 2.642-113.0<br />

<strong>WRP</strong> <strong>10000</strong><br />

Fresh water supply 2.642-114.0<br />

<strong>WRP</strong> <strong>20000</strong><br />

Circulation pump 2.642-352.0<br />

Installing the unit (only for<br />

experts)<br />

Notice<br />

The equipment may only be installed by an<br />

– mechanic of <strong>Kärcher</strong><br />

– or an from <strong>Kärcher</strong> authorized individual<br />

Preparing the installation place<br />

The follo<strong>win</strong>g requirements are necessary<br />

in order to install the equipment:<br />

– frost-free room with adequate ventilation<br />

<strong>and</strong> exhausts<br />

– Floor path for collecting sludge<br />

– Water <strong>and</strong> electrical connection: see<br />

"Technical data"<br />

– horizontal, even foundation<br />

– Protect the plant against direct sunlight<br />

<strong>and</strong> spray water<br />

– Sufficiently illuminate the installation<br />

site<br />

– The floor must be freely accessible.<br />

22 EN<br />

Unpack the equipment<br />

Unpack the equpiment <strong>and</strong> dispose of the<br />

packing material properly.<br />

Water installation<br />

The water installation depends on the specific<br />

conditions of the existing plant components<br />

such as<br />

– Type <strong>and</strong> model of washing unit<br />

– Type <strong>and</strong> models of building-side components<br />

(sludge collector, pump basin, etc.)<br />

– Nominal widtht, lengths <strong>and</strong> type of<br />

channels<br />

Hence, the water installation must be carried<br />

out according to the specific project<br />

documents.<br />

Danger<br />

Risk of injury on account of tripping <strong>and</strong> falling.<br />

Lay the hoses of the plant in such a way<br />

that they do not pose a risk for tripping <strong>and</strong><br />

falling.<br />

Electrical connection<br />

Danger<br />

Risk of electrical voltage. All electrical installations<br />

may only be done by an electrician<br />

according to the local regulations.<br />

The plant must be secured through a wrong<br />

current protection switch with a triggering<br />

current lesser than or equal to 30 mA.<br />

– The appliance may only be connected<br />

to alternating current.<br />

– The appliance may only be connected<br />

to an electrical supply which has been<br />

installed by an electrician in accordance<br />

with IEC 60364.<br />

– The voltage indicated on the type plate<br />

must correspond to the voltage of the<br />

electrical source.<br />

– The appliance should always be connected<br />

to the electrical mains using a<br />

plug. It is forbidden to permanently connect<br />

the appliance to the power supply.<br />

The plug is only for mains separation.<br />

- 10<br />

CE declaration<br />

We hereby declare that the machine described<br />

below complies with the relevant<br />

basic safety <strong>and</strong> health requirements of the<br />

EU Directives, both in its basic design <strong>and</strong><br />

construction as well as in the version put<br />

into circulation by us. This declaration shall<br />

cease to be valid if the machine is modified<br />

without our prior approval.<br />

Product: Water treatment plant<br />

Type: 1.217-xxx<br />

Relevant EU Directives<br />

2006/42/EC (+2009/127/EC)<br />

2006/95/EC<br />

2004/108/EC<br />

Applied harmonized st<strong>and</strong>ards<br />

EN 60204–1<br />

EN 55014–1: 2006 + A1: 2009<br />

EN 55014–2: 1997 + A2: 2008<br />

EN 61000–3–2: 2006 + A2: 2009<br />

EN 61000–3–3: 2008<br />

The undersigned act on behalf <strong>and</strong> under<br />

the power of attorney of the company management.<br />

CEO Head of Approbation<br />

Authorised Documentation Representative<br />

S. Reiser<br />

Alfred <strong>Kärcher</strong> GmbH Co. KG<br />

Alfred-<strong>Kärcher</strong>-Str. 28 - 40<br />

71364 Winnenden (Germany)<br />

Phone: +49 7195 14-0<br />

Fax: +49 7195 14-2212