TWINCAT PLC – Lista de erros<br />
BECKHOFF New Automation Technology<br />
the qualifier.<br />
4359 Invalid Qualifier: '%s' In the box on the left hand of the action name enter a<br />
qualifier for the IEC action.<br />
4360 Time Constant<br />
expected after qualifier<br />
'%s'<br />
4361 '%s' is not the name of<br />
an action<br />
Enter next to the box on the left hand of the action name a<br />
time constant behind the qualifier.<br />
Enter next to the box on the right hand of the qualifier the<br />
name of an action or the name of a variable which is defined<br />
in the project.<br />
Insert a boolean variable or a valid action name.<br />
4362 Nonboolean expression<br />
used in action: '%s'<br />
4363 IEC-Step name already Please rename the step or the variable.<br />
used for variable:<br />
''<br />
4364 A transition must be a The result of the transition expression must be of type<br />
boolean expression BOOL.<br />
4365 Time Constant<br />
Open dialog ‚step attributes’ for the step '' and enter<br />
expected after qualifier a valid time variable or time constant<br />
''<br />
4366 The label of the parallel Enter a valid identifier next to the triangle which marks the<br />
branch is no valid<br />
jump label.<br />
identifier: ''<br />
4367 The label '' is There is already a jump label or a step with this name.<br />
already used<br />
Please rename correspondingly.<br />
4368 Action '' is used The action '' is used in the POU as well as in one or<br />
in multiple step chains, several actions of the POU.<br />
where one is containing<br />
the other!<br />
4369 Exactly one network There are used several FBD resp. LD networks for a<br />
required for a transition transition. Please reduce to 1 network.<br />
4370 Additional lines found Remove the not needed lines at the end of the transition.<br />
after correct ILtransition<br />
4371 Invalid characters<br />
Remove the not needed characters at the end of the<br />
following valid<br />
transition.<br />
expression: '<br />
4400 Import / conversion of The POU cannot be converted to IEC 61131-3 completely.<br />
POU '%s' contains<br />
errors resp. is not<br />
complete.<br />
4401 S5 time constant %lu There is no valid BCD coded time in the accu.<br />
seconds is too big<br />
(max. 9990s).<br />
4402 Direct access to I/Os Make sure that you only access variables which are defined<br />
allowed only.<br />
as input or output.<br />
4403 STEP5/7 instruction Some STEP5/7 commands are not convertable to IEC<br />
invalid or not<br />
61131-3, e.g. CPU commands like MAS.<br />
convertible to IEC<br />
61131-3.<br />
4404 STEP5/7 operand<br />
Some STEP5/7 operands are not convertable to IEC 61131-<br />
invalid or not<br />
3 respectively an operand is missing.<br />
convertible to IEC<br />
61131-3.<br />
4405 Reset of a STEP5/7 The corresponding IEC timer have no reset input.<br />
timer cannot be<br />
converted into IEC<br />
61131-3.<br />
4406 STEP5/7 Counter<br />
There is no valid BCD coded counter constant in the accu.<br />
constant out of range<br />
(max. 999).<br />
4407 STEP5 instruction not Some STEP5/7 instructions cannot be converted to IEC<br />
convertible to IEC<br />
61131-3, e.g. DUF.<br />
61131-3.<br />
4408 Bit access of timer or Special timer/counter commands are not convertable into<br />
counter words not<br />
IEC 61131-3.<br />
convertible into IEC<br />
61131-3.<br />
4409 Contents of ACCU1 or A command, which connects the both accus, cannot be<br />
<strong>BRESIMAR</strong> Anexo B – 15 de 18