03.10.2019 Views

BRESIMAR(asaTek)-Beckhoff-Livro Formação Técnica TwinCAT 2

BECKHOFF - TwinCAT 2 Livro de Formação Técnica v1.2/2009 BRESIMAR AUTOMAÇÃO / asaTek Autoria : Jorge Andril

BECKHOFF - TwinCAT 2
Livro de Formação Técnica v1.2/2009
BRESIMAR AUTOMAÇÃO / asaTek
Autoria : Jorge Andril

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TWINCAT PLC – Lista de erros<br />

BECKHOFF New Automation Technology<br />

ACCU2 undefined, not converted, because the accu values are not defined.<br />

convertible into IEC<br />

61131-3.<br />

4410 Called POU not in<br />

Import the called POU.<br />

project.<br />

4411 Error in global variable Please check the SEQ file.<br />

list.<br />

4412 Internal error no.11 Please contact the PLC manufacturer.<br />

4413 Error in format of line in<br />

data block<br />

In the code which should be imported there is an erroneous<br />

date.<br />

4414 FB/FX name missing. In the original S5D file the symbolic name of an (extended)<br />

POU is missing.<br />

4415 Instruction after block A protected POU cannot get imported<br />

end not allowed.<br />

4416 Invalid Command The S5/S7 command cannot be disassembled.<br />

4417 Comment not closed Close the comment with "*)".<br />

4418 FB/FX-Name too long The symbolic name of an (extended) POU is to long.<br />

(max. 8 characters)<br />

4419 Expected format of line Correct the line correspondingly.<br />

""(* Name: *)""<br />

4420 Name of FB/FX<br />

Check the POUs.<br />

parameter missing<br />

4421 Type of FB/FX<br />

Check the POUs.<br />

parameter invalid<br />

4422 Type of FB/FX<br />

Check the POUs.<br />

parameter missing<br />

4423 Invalid FB/FX call<br />

Check the interface of the POU.<br />

parameter<br />

4424 Warning: FB/FX for call<br />

either missing or<br />

parameters invalid or<br />

The called POU is not imported yet or is not correct or has<br />

no parameters (in the last case you can ignore the error<br />

message).<br />

has '0' parameters<br />

4425 Definition of label<br />

The aim (label) of the jump is not defined.<br />

missing<br />

4426 POU does not have a Modify the POU name.<br />

valid STEP 5 block<br />

name, e.g. PB10<br />

4427 Timer type not declared Add a declaration of the timer in the global variables list.<br />

4428 Maximum number of You may not use more than seven open brackets.<br />

open STEP5 brackets<br />

exceeded<br />

4429 Error in name of formal The parameter name may not exceed four characters.<br />

parameter<br />

4430 Type of formal<br />

parameter not IECconvertible<br />

4431 Too many<br />

'VAR_OUTPUT'<br />

parameters for a call in<br />

STEP5 STL<br />

4432 Labels within an<br />

expression are not<br />

allowed<br />

In IEC 61131-3 Timer, counter and POUs cannot be<br />

converted as formal parameters.<br />

A POU may not contain more than 16 formal parameters as<br />

outputs.<br />

In IEC 61131-3 jump labels may not be inserted at any<br />

desired position.<br />

4434 Too many labels A POU may not contain more than 100 labels.<br />

4435 After jump / call, a new After jump or call a Load command LD must follow.<br />

expression must start<br />

4436 Bit result undefined, not<br />

convertible to IEC<br />

61131-3.<br />

The command which is used by VKE cannot get converted,<br />

because the value of the VKE is not known.<br />

4437 Type of instruction and A bit command is used for a word operand or the other way<br />

operand are not<br />

round.<br />

compatible<br />

4438 No data block opened<br />

(insert instruction C DB<br />

before)<br />

Insert a „A DB“.<br />

4500 Unrecognized variable<br />

or address<br />

The watch variable is not declared within the project. By<br />

pressing you get the input assistant which lists the<br />

<strong>BRESIMAR</strong> Anexo B – 16 de 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!