BRESIMAR(asaTek)-Beckhoff-Livro Formação Técnica TwinCAT 2
BECKHOFF - TwinCAT 2 Livro de Formação Técnica v1.2/2009 BRESIMAR AUTOMAÇÃO / asaTek Autoria : Jorge Andril
BECKHOFF - TwinCAT 2
Livro de Formação Técnica v1.2/2009
BRESIMAR AUTOMAÇÃO / asaTek
Autoria : Jorge Andril
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TWINCAT PLC – Lista de erros<br />
BECKHOFF New Automation Technology<br />
ACCU2 undefined, not converted, because the accu values are not defined.<br />
convertible into IEC<br />
61131-3.<br />
4410 Called POU not in<br />
Import the called POU.<br />
project.<br />
4411 Error in global variable Please check the SEQ file.<br />
list.<br />
4412 Internal error no.11 Please contact the PLC manufacturer.<br />
4413 Error in format of line in<br />
data block<br />
In the code which should be imported there is an erroneous<br />
date.<br />
4414 FB/FX name missing. In the original S5D file the symbolic name of an (extended)<br />
POU is missing.<br />
4415 Instruction after block A protected POU cannot get imported<br />
end not allowed.<br />
4416 Invalid Command The S5/S7 command cannot be disassembled.<br />
4417 Comment not closed Close the comment with "*)".<br />
4418 FB/FX-Name too long The symbolic name of an (extended) POU is to long.<br />
(max. 8 characters)<br />
4419 Expected format of line Correct the line correspondingly.<br />
""(* Name: *)""<br />
4420 Name of FB/FX<br />
Check the POUs.<br />
parameter missing<br />
4421 Type of FB/FX<br />
Check the POUs.<br />
parameter invalid<br />
4422 Type of FB/FX<br />
Check the POUs.<br />
parameter missing<br />
4423 Invalid FB/FX call<br />
Check the interface of the POU.<br />
parameter<br />
4424 Warning: FB/FX for call<br />
either missing or<br />
parameters invalid or<br />
The called POU is not imported yet or is not correct or has<br />
no parameters (in the last case you can ignore the error<br />
message).<br />
has '0' parameters<br />
4425 Definition of label<br />
The aim (label) of the jump is not defined.<br />
missing<br />
4426 POU does not have a Modify the POU name.<br />
valid STEP 5 block<br />
name, e.g. PB10<br />
4427 Timer type not declared Add a declaration of the timer in the global variables list.<br />
4428 Maximum number of You may not use more than seven open brackets.<br />
open STEP5 brackets<br />
exceeded<br />
4429 Error in name of formal The parameter name may not exceed four characters.<br />
parameter<br />
4430 Type of formal<br />
parameter not IECconvertible<br />
4431 Too many<br />
'VAR_OUTPUT'<br />
parameters for a call in<br />
STEP5 STL<br />
4432 Labels within an<br />
expression are not<br />
allowed<br />
In IEC 61131-3 Timer, counter and POUs cannot be<br />
converted as formal parameters.<br />
A POU may not contain more than 16 formal parameters as<br />
outputs.<br />
In IEC 61131-3 jump labels may not be inserted at any<br />
desired position.<br />
4434 Too many labels A POU may not contain more than 100 labels.<br />
4435 After jump / call, a new After jump or call a Load command LD must follow.<br />
expression must start<br />
4436 Bit result undefined, not<br />
convertible to IEC<br />
61131-3.<br />
The command which is used by VKE cannot get converted,<br />
because the value of the VKE is not known.<br />
4437 Type of instruction and A bit command is used for a word operand or the other way<br />
operand are not<br />
round.<br />
compatible<br />
4438 No data block opened<br />
(insert instruction C DB<br />
before)<br />
Insert a „A DB“.<br />
4500 Unrecognized variable<br />
or address<br />
The watch variable is not declared within the project. By<br />
pressing you get the input assistant which lists the<br />
<strong>BRESIMAR</strong> Anexo B – 16 de 18