<strong>Electrophoresis</strong> · Accessories<br />
Roth Power Supplies<br />
The Roth series - powerful and inexpensive Power Supplies for<br />
electrophoresis and blotting<br />
Three units for all applications in electrophoresis. The very inexpensive<br />
Power Supply MINI has been developed for horizontal mini gels, rapid<br />
bench top-analyses of nucleic acids and for students courses. The<br />
STANDARD version is best suited for all horizontal routine gels and for<br />
vertical mini gel electrophoresis. The versatile Roth Power Supply BLOT is<br />
recommended for maximum application flexibility in the lab, for largedimension<br />
horizontal gels, vertical maxi gels (e. g. 20 x 20 cm),<br />
cold room operation and blotting.<br />
• Compact<br />
• Easy to operate<br />
• Constant parameters<br />
• Timer with alarm function<br />
• Connection with 2 or 4 units possible<br />
• Comply to all relevant safety standards<br />
• 2 years warranty<br />
Technical specifications:<br />
Type ➀ MINI ➁ STANDARD ➂ BLOT<br />
Model Mini 300 VS MP-300 MP-3AP<br />
Voltage (V)<br />
50, 100, 150,<br />
200, 250, 300<br />
0-300 0-300<br />
Max. intensity of current 400 mA 700 mA 3000 mA<br />
Max. output 60 W 150 W 300 W<br />
Timer X 1-999 mins 1-999 mins<br />
Volt-hours 49.995 kVh<br />
Display LCD display LCD display Matrix display<br />
Resolution 50 V 1 V, 1 mA 1 V, 10 mA, 1 W<br />
Output type Constant V<br />
Constant V or mA Constant V,<br />
mA or W<br />
Programs X<br />
X 16 files with 6<br />
parameters each<br />
Outlets: parallel socket pairs<br />
2 (4 mm) 4 (4 mm) 4 (4 mm)<br />
Min. load resistor 5 Ω 3 Ω 0.1 Ω<br />
Safety<br />
‚No load‘<br />
detection<br />
‚No load‘ and<br />
leakage detection<br />
‚No load‘, leakage<br />
and detection<br />
Ambient temp. 15-40 °C 4-40 °C 4-40 °C<br />
Dimensions (cm) 10.5 x 15 x 7.5 14 x 16 x 7 18 x 28 x 14<br />
Weight 0.6 kg 2.5 kg 2.5 kg<br />
Current 220 V<br />
Roth Power Supply MINI<br />
For horizontal mini gels, rapid analyses of nucleic acids and for students<br />
courses.<br />
Voltage (V) Intensity of current (mA) Output (W) Art. No. Pack Qty. €<br />
max. 300 max. 400 max. 60 2907.1 1 464,40<br />
Roth Power Supply STANDARD<br />
For standard applications, all middle sized horizontal gels (routine gels)<br />
and for vertical mini gels. Suitable for cold-room operation.<br />
Voltage (V) Intensity of current (mA) Output (W) Art. No. Pack Qty. €<br />
max. 300 max. 700 max. 150 2908.1 1 743,90<br />
Roth Power Supply BLOT<br />
For large dimension horizontal gels, vertical maxi gels and blotting.<br />
For high flexibility in application. Suitable for cold-room operation.<br />
Voltage (V) Intensity of current (mA) Output (W) Art. No. Pack Qty. €<br />
max. 300 max. 3000 max. 300 2909.1 1 1094,35<br />
Accessories<br />
<strong>Electrophoresis</strong> Cables<br />
Suitable for up to 1000 volt. Cable length 1 m.<br />
∅ socket (mm) ∅ plug (mm) Art. No. Pack Qty. (Pair) €<br />
4 4 N843.1 1 64,45<br />
Adapters<br />
By using the appropriate pair of adapters, electrophoresis cables may fit<br />
to any customary power supply.<br />
∅ socket (mm) ∅ plug (mm) Art. No. Pack Qty. (Pair) €<br />
2 4 T843.1 1 15,00<br />
4 2 K294.1 1 7,50<br />
4 4 K295.1 1 5,25<br />
Silicone Sealing Hose<br />
for horizontal gel casting trays (Art.No. N575.1 and N595.1), ∅ 4 mm<br />
Art. No. Pack Qty. €<br />
T811.1 ~1 m 13,75<br />
Platinum Spare Electrode<br />
for vertikal and horizontal electrophoresis units, ∅ 0,2 mm<br />
Art. No. Pack Qty. €<br />
T794.1 500 mm 72,85<br />
Platinum wire<br />
99.9 %<br />
∅ 0,3 mm<br />
Pt<br />
Global Step - Email : Office@global-step.net<br />
Telefon : (+4) 0742 095 539<br />
Tel/Fax : (+4) 031 104 85 87<br />
Mobil : (+4) 0720 095 539, 0723 442 593<br />
8415.1 100 mm plastic 56,15 €<br />
8415.2 500 mm plastic 190,80 €<br />
891<br />
Elektrophorese