Installation<br />

CAUTION:<br />

When fabricating the coolant supply piping (Figure A—11), always install the throttle<br />

valve on the discharge side of the manifold rather than the inlet side. This will ensure that<br />

the coolers are always flooded and that no air locks will form to restrict flow.<br />

After fabrication of the cooling water piping is complete and before the initial compressor startup,<br />

install temporary filter screens in the supply lines just before entry to the heat exchangers. Flush the<br />

pipes thoroughly, and when it is determined that the supply piping is completely free of any foreign<br />

matter, remove the screens. Reconnect the compressor manifold, and verify that there are no external<br />

leaks. To verify that there are no internal leaks, open the condensate drains of the intercoolers and<br />

aftercooler.<br />

3” Victaulic Connection<br />

Figure A—11. Typical Water Supply and Return Piping<br />

E<br />

C<br />

D<br />

A<br />

B<br />

C<br />

A<br />

B<br />

A. Temperature Gauge<br />

B. Pressure Gauge<br />

C. Shut-Off Valve<br />

D. Throttle Valve<br />

E. Drain Connection<br />

A—21