Maintenance<br />
Scheduled Maintenance<br />
Table 5—2 lists suggested intervals for prescribed scheduled maintenance procedures such as those<br />
involving filters, lubrication, and other inspections and/or adjustments. Bear in mind, however, that<br />
these intervals may vary with operating conditions and/or actual hours of machine operation. Some<br />
items may require attention more or less frequently as circumstances dictate.<br />
Scheduled Maintenance Procedures<br />
When servicing the <strong>Turbo</strong> Air <strong>3000</strong> <strong>Centrifugal</strong> <strong>Compressor</strong>, use only genuine Joy ® and Cooper<br />
<strong>Turbo</strong>compressor replacement parts and recommended supplies available through Cooper<br />
<strong>Turbo</strong>compressor and/or authorized representatives.<br />
Weekly:<br />
(or after about 150 hours of operation)<br />
3 Inlet air filter elements inspected, replaced if required<br />
3 Oil reservoir venting system filter elements inspected, replaced if required<br />
3 Bypass valve filter checked (if supplied)<br />
Every Six Months:<br />
(or after about 4000 hours of operation)<br />
3 Oil reservoir venting system filter element changed<br />
3 Oil system filter element changed<br />
3 Lubrication system oil tested and changed if required<br />
3 Coolant chemically tested<br />
3 Bypass valve lubricated (if required – check instructions)<br />
3 Inlet guide vane assembly drive screw lubricated<br />
3 Main drive coupling inspected and lubricated.<br />
3 Drive motor ball bearings lubricated with recommended grease. *<br />
3 Oil pump motor lubricated with recommended grease<br />
3 Discharge air check valve inspected<br />
*Refer to the motor instructions for specific interval guidelines.<br />
Table 5—2 Scheduled Maintenance Procedures<br />
5—5