The Turbo Air® 3000 Centrifugal Compressor Compressor Handbook
The Turbo Air® 3000 Centrifugal Compressor Compressor Handbook
The Turbo Air® 3000 Centrifugal Compressor Compressor Handbook
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>The</strong> Control System<br />
<strong>The</strong> Vantage Control Panel<br />
<strong>The</strong> major components of the Vantage Controller are mounted in a weatherproof electrical enclosure<br />
with a NEMA 4 rating. One or more Main Logic Modules (MLM) are included in the panel. Each MLM<br />
contains a power supply, a microprocessor, and an I/O (input / output) segment. Depending upon the<br />
particular application, up to two additional slave MLM units may accompany the master MLM to<br />
increase I/O capacity.<br />
Each master MLM also contains the hardware to support a User Interface Module (UIM). <strong>The</strong> UIM is a<br />
full-page, back-lit liquid crystal LCD display with an integrated 15 key, tactile keypad. <strong>The</strong> display<br />
provides 20 lines by 80 characters of detailed information on the operational condition and settings of<br />
the controller.<br />
<strong>The</strong> acceptable operating environment of the control panel includes an operating temperature range<br />
of 32ºF to 140ºF (0ºC to 60ºC), and a maximum 95% relative humidity (non-condensing). <strong>The</strong> storage<br />
temperature range is -4ºF to 140ºF (-20ºC to 60ºC).<br />
<strong>The</strong> source power is 100 - 240 VAC, 50 or 60 Hz. A 10-amp fuse protects the MLM circuitry. All wiring,<br />
including grounding, must be in accordance with local codes and the National Electric Code (NEC) in<br />
the USA.<br />
CAUTION:<br />
<strong>The</strong> MLM is neither designed not intended to supply power to any other device.<br />
Do not wire any other devices from the MLM.<br />
<strong>The</strong> display, or UIM, receives electrical power from the MLM through the DB9 cable with connectors.<br />
Do not attempt to supply power to the UIM from any other source other than the MLM.<br />
<strong>The</strong> Vantage Controller operates similarly to a personal computer (PC). Operating system software is<br />
stored in flash memory located in the MLM. <strong>The</strong> operating system provides a real time, multi-tasking<br />
environment for control programs. Control programs are loaded and saved to flash memory prior to<br />
installation. Once loaded, these programs are maintained in memory by a small battery or saved to flash<br />
memory. It is not necessary to load programs into the Vantage Controller except during certain special<br />
installations, or if a new MLM is installed.<br />
<strong>The</strong> MLM and UIM contain no user serviceable parts.<br />
Cleaning - If the MLM becomes dirty, use only a dry cloth to clean the part. Never apply water or any<br />
solvent. If the display, or UIM, should become dirty, a mild detergent can be used for cleaning. Use a<br />
soft, non-abrasive cloth to clean the display. Do not submerge any part.<br />
3—3