Control Methods<br />

Vantage offers three distinct load control methods to provide flexibility in meeting widely varying<br />

jobsite compressed air needs.<br />

C—4<br />

· Auto – Offline*<br />

· Auto – Standby*<br />

· Auto – Unload<br />

Each Vantage control method uses all five valve control loops shown Table C—1. Detailed descriptions<br />

of these methods appear latter in this Appendix.<br />

*Note: Both the Auto-Offline and Auto-Standby mode require a modulating blow off<br />

discharge valve.<br />

Load Control Loops<br />

<strong>The</strong> Vantage control system performs load control through five independent control loops. Each loop<br />

modulates either the inlet valve or the discharge valve, also called the Modulating Blow Off Valve or<br />

MBOV<br />

Inlet Valve Control Discharge Valve Control<br />

Control loop Setpoint Control loop Setpoint<br />

Maximum Power Maximum Motor Load Blow-Off System System Pressure<br />

Pressure Offset<br />

System Pressure System Pressure Blow-Off Discharge Max. Discharge<br />

Pressure Pressure<br />

Minimum Flow Surge Control Offset<br />

A description of the setpoints follows.<br />

Table C—1 Vantage Control Loops and their Setpoints