The Turbo Air® 3000 Centrifugal Compressor Compressor Handbook
The Turbo Air® 3000 Centrifugal Compressor Compressor Handbook
The Turbo Air® 3000 Centrifugal Compressor Compressor Handbook
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>The</strong> <strong>Turbo</strong> Air <strong>3000</strong> <strong>Centrifugal</strong> <strong>Compressor</strong> Operator’s Manual<br />
Routine Shutdown—Local Control<br />
Use the following procedure to shutdown the compressor under normal conditions.<br />
4—6<br />
CAUTION:<br />
If the compressor is to be shutdown for an extended period in a cold environment, drain<br />
all water from the compressor's cooling system after the shutdown. Water in the heat<br />
exchangers may freeze and cause damage to the internal tubes. An alternative to draining<br />
is to maintain some minimum flow through the coolers.<br />
1. Press the STOP key.<br />
<strong>The</strong> automated stop sequence, including stopping the motor, begins.<br />
Stopping<br />
Description Status<br />
1. Motor Enable = OFF Completed<br />
2. Oil Pump = OFF Waiting 2<br />
(Note: Messages and data displayed on stop sequence screen may differ among systems.)<br />
2. When you press the STOP key, the Vantage control system software tells the bypass valve (or<br />
blow-off valve) to open and the inlet guide vanes (or other throttling device) to close<br />
completely. (This takes 10-15 seconds.) In addition to the closing of the inlet, the<br />
automated stop sequence begins.<br />
3. Close the air system block valve.*<br />
4. Open the condensate drain bypass valves. (May occur automatically as part of sequence.)*<br />
5. Allow the cooling water and oil to circulate for at least 30 minutes to remove heat.<br />
6. Turn off the water supply, if not controlled automatically. (May occur automatically as part of<br />
sequence.)<br />
7. Stop the electric oil pump, if wired separately. (May occur automatically as part of sequence.)<br />
8. Rack out the drive motor starter disconnect.<br />
9. Turn off the reservoir venting system.