<strong>The</strong> <strong>Turbo</strong> Air <strong>3000</strong> <strong>Centrifugal</strong> <strong>Compressor</strong> Operator’s Manual<br />

Routine Shutdown—Local Control<br />

Use the following procedure to shutdown the compressor under normal conditions.<br />

4—6<br />

CAUTION:<br />

If the compressor is to be shutdown for an extended period in a cold environment, drain<br />

all water from the compressor's cooling system after the shutdown. Water in the heat<br />

exchangers may freeze and cause damage to the internal tubes. An alternative to draining<br />

is to maintain some minimum flow through the coolers.<br />

1. Press the STOP key.<br />

<strong>The</strong> automated stop sequence, including stopping the motor, begins.<br />

Stopping<br />

Description Status<br />

1. Motor Enable = OFF Completed<br />

2. Oil Pump = OFF Waiting 2<br />

(Note: Messages and data displayed on stop sequence screen may differ among systems.)<br />

2. When you press the STOP key, the Vantage control system software tells the bypass valve (or<br />

blow-off valve) to open and the inlet guide vanes (or other throttling device) to close<br />

completely. (This takes 10-15 seconds.) In addition to the closing of the inlet, the<br />

automated stop sequence begins.<br />

3. Close the air system block valve.*<br />

4. Open the condensate drain bypass valves. (May occur automatically as part of sequence.)*<br />

5. Allow the cooling water and oil to circulate for at least 30 minutes to remove heat.<br />

6. Turn off the water supply, if not controlled automatically. (May occur automatically as part of<br />

sequence.)<br />

7. Stop the electric oil pump, if wired separately. (May occur automatically as part of sequence.)<br />

8. Rack out the drive motor starter disconnect.<br />

9. Turn off the reservoir venting system.